Assembly
06.00|PZB-plus |en
25
1 Turn in the sensor (7) of the magnetic switch into the groove
until it bears against the stop (8) (if available).
2 If there is no terminal stop, then slide the magnetic switch ac-
cording to dimension l2 (bottom edge of gripper up to front
side of sensor) or according to dimension l1 (bottom edge of
gripper up to double arrow on sensor) and then clamp with
the mounting screw.
3 Fix the sensor with an Allen wrench.