Maintenance
09.00 | PWG-plus | Assembly and operating manual | en | 389495
37
7.4.2 Variant with maintenance of gripping force (O.D. gripping)
Position of the item numbers:
WARNING
Risk of injury due to spring forces!
The cover is under spring tension.
•
Carefully disassemble the product.
Ø
Remove compressed air lines
Ø
Remove cover (6).
Ø
WARNING Risk of injury due to spring forces! The cylinder
piston and the cover are under spring tension. Carefully
disassemble the product.
Clamp the product between the base
jaws (2) and the cover (10) in the vice so that the four screws
(46) can still be removed.
Ø
Unscrew screws (46).
Ø
Open the vice carefully and remove the lid (10).
Ø
Assembly device cylinder piston with
44]place the device (101) (size
50-100) or the device (103) (size 125-240) on the PWG-plus
housing (1) using the centering sleeves (19) and screw both
parts together with the screws (102) or (104). Sizes 125-240
require a two-piece fixture. Position fixture part 2 (105) in part 1
(103) and screw it together with the screws (106).
Ø
Unscrew screw (45).
Ø
For sizes 125-240, unscrew the screws (106) evenly and remove
part 2 from the device (105).
Ø
Unscrew screws (104) (sizes 125-240) or screws (102) (sizes
50-100) evenly and carefully remove the device (103) or (101).
Ø
Remove the cylinder piston (60) from the case (1).
Ø
Loosen grub screws (21) in base jaws (2).
Ø
Remove bolt (5).
Ø
Pull out base jaws (2) from case (1).
Ø
Push the piston assembly (3, 4 and 39) out of the case(1) in an
upwards motion.