Troubleshooting
46
06.00 | PPU-P | Assembly and Operating Manual | en | 389323
6 Troubleshooting
6.1 No Pick&Place motion
Possible cause
Corrective action
Pressure drops below minimum.
Check air supply.
Pressure lines connected incorrectly.
Check compressed air lines.
Sensor inaccurately adjusted or defective.
Readjust or change sensor.
Product is actuated incorrectly.
Check actuation based on sequence
diagram.
6.2 Cycle speed is not reached?
Possible cause
Corrective action
Use of unsuitable valves.
Check valve switching times and consult
SCHUNK contact person if necessary.
Shock absorber extended too far.
Readjustshock absorber setting.
Fallen short of nominal pressure.
Check air supply.
Permissible lengths of connection lines
exceeded.
Keep compressed air lines between the
product and directional control valve as
short as possible.
Switching points have not been set correctly. Check the UH and UV sensor settings.
Mounting and adjustment of sensors IN
Compressed air lines are not installed
optimally.
Check compressed air lines.
Inner diameters of compressed air lines are
of sufficient size in relation to compressed
air consumption.
Flow rate of valve is sufficiently large
relative to the compressed air consumption.