SCHUNK MV 15 Assembly And Operating Manual Download Page 2

Imprint 

 

  

 

01.03|MV 15 - 30|en 

 

 

 

Imprint 

  

 

Copyright:

 

This manual remains the copyrighted property of SCHUNK GmbH & Co. KG. It is solely 
supplied to our customers and operators of our products and forms part of the product. 
This documentation may not be duplicated or made accessible to third parties, in 
particular competitive companies,  
without our prior permission. 

Technical changes:

 

We reserve the right to make alterations for the purpose of technical improvement. 

Document number:

 GAS 380381 

Edition:

 01.03 |06/05/2015|en  

© SCHUNK GmbH & Co. KG 
All rights reserved. 
 
 
 

  

  

Dear customer, 
congratulations on choosing a SCHUNK product. By choosing SCHUNK, you have opted for  
the highest precision, top quality and best service. 
You are going to increase the process reliability of your production and achieve best  
machining results – to the customer's complete satisfaction. 
SCHUNK products are inspiring. 
Our detailed assembly and operation manual will support you. 
Do you have further questions? You may contact us at any time – even after purchase. 
 
Kindest Regards 

  

  

Yours SCHUNK GmbH & Co. KG 
Spann- und Greiftechnik 
Bahnhofstr. 106 – 134 
D-74348 Lauffen/Neckar 
Tel. +49-7133-103-0 
Fax +49-7133-103-2399 
[email protected] 
www.schunk.com 

 
 
 

 

  

 

Summary of Contents for MV 15

Page 1: ...Translation of the original manual Micro valve MV 15 30 Assembly and operating manual Superior Clamping and Gripping...

Page 2: ...06 05 2015 en SCHUNK GmbH Co KG All rights reserved Dear customer congratulations on choosing a SCHUNK product By choosing SCHUNK you have opted for the highest precision top quality and best service...

Page 3: ...2 4 Personnel qualification 6 2 5 The use of personal protective equipment 7 2 6 Notes on particular risks 7 3 Warranty 8 4 Scope of delivery 8 5 Technical data 9 6 Assembly and installation 10 6 1 Me...

Page 4: ...the following signal words and symbols are used for safety notes DANGER Danger for persons Non compliance will inevitably cause irreversible injury or death WARNING Dangers for persons Ignoring a safe...

Page 5: ...defined applica tion parameters 5 Page 9 The product is not a safety component in accordance with the EC Machine Directive 2006 42 EC and must not be used in safety relevant parts of machine control...

Page 6: ...ve equipment per EC Machinery Directive Constructional changes attachments or modifications Additional drill holes threads or attachments that are not offered as accessories by SCHUNK may be attached...

Page 7: ...ism or the movement area of the unit Perform maintenance modifications and additions outside the danger zone For all work secure the product against accidental operation Take particular care during ma...

Page 8: ...from the production facility un der the following conditions Observe the applicable documents 1 2 Page 4 Observance of the ambient conditions and operating conditions 2 2 Page 5 Parts touching the wor...

Page 9: ...M8 plug cable extension with open wire strand Outer diameter connection cable mm 3 1 0 15 Power consumption W see data sheet catalog Operating data for compressed air connection Pressure medium Filte...

Page 10: ...l fitting tightening torque Connection with screws max tightening torque Nm M3 0 7 M5 1 5 G1 8 10 0 G1 4 15 0 Comply with the following procedure when mounting the micro valve If the micro valve is su...

Page 11: ...connection cable so there are no tensile and twisting forces on the valve cover Tensile and twisting forces can cause the screw cap to come loose and lead to contact problems PIN allocation M8 plug a...

Page 12: ...ion cable and accessory 4 3 Unscrew the valve cartridge 2 from the swivel fitting 1 Installing and connecting the micro valve WARNING Risk of injury when working on the micro valve Switch off the ener...

Page 13: ...f the swivel fitting 1 in this positi on Maximum torque see Swivel fitting tightening torque table 4 Screw the valve cartridge 2 into the swivel fitting 1 as far as possible Maximum torque 3 Nm 5 Scre...

Page 14: ...nection cable when the valve cover is put on Valve cover Carry out the following steps if the position of the connection cab le should be changed 1 Unscrew the knurled nut 1 of the valve cover 3 from...

Page 15: ...ly able to switch with this pressure support 1 Supply pressure in the pressure range of the micro valve see catalog data sheet 2 Apply the operating voltage The LED on a screw cap lights up 3 Check wh...

Page 16: ...ble with micro valve with a valve cover and recovery diode Make the correct connection assignment 6 2 Page 11 Supply voltage too low Check the supply voltage see catalog data sheet Valve is not tight...

Page 17: ...e If the requirement on the compressed air are not complied with clean the micro valve at the following points The piston sealing face P and the sealing contour in the swivel fitting can be cleaned wi...

Page 18: ...Notes 18 01 03 MV 15 30 en Notes...

Page 19: ...Notes 01 03 MV 15 30 en 19 Notes...

Page 20: ...20 01 03 MV 15 30 en...

Reviews: