Assembly and installation
10
01.03|MV 15 - 30|en
Assembly and installation
Mechanical connection
NOTICE
Damage to the connection cable is possible!
The connection cable could be damaged by twisting when a valve
cartridge with a fixed cover is mounted.
• The connection cable must be able to move freely when a
valve cartridge with a fixed cover is screwed in.
Swivel fitting tightening torque
Connection with screws
max. tightening torque [Nm]
M3
0.7
M5
1.5
G1/8"
10.0
G1/4"
15.0
Comply with the following procedure when mounting the micro
valve:
• If the micro valve is supplied as a complete component,
dismantle the micro valve into its individual components and
then install the individual components:
– Dismantling the micro valve into its individual components,
– Installing the individual components,
• If the micro valve is supplied in individual components, install