Technical data
18
09.00 | MPG | Assembly and Operating Manual | en | 389213
3 Technical data
Designation
MPG
Pressure medium
Compressed air, compressed air
quality according to
ISO 8573-1:7 4 4
Nominal working pressure [bar]
6
Min. pressure [bar]
without gripping force
maintenance
with gripping force maintenance
2
4
Max. pressure [bar]
without gripping force
maintenance
with gripping force maintenance
8
6.5
Noise emission [dB(A)]
≤ 70
More technical data is included in the catalog data sheet.
Whichever is the latest version.
Ambient conditions and operating conditions
Designation
MPG
Ambient temperature [°C]
min.
max.
+5
+90
Protection class IP *
30
Noise emission [dB(A)]
≤ 70
* For use in dirty ambient conditions (e.g. sprayed water, vapors,
abrasion or processing dust) SCHUNK offers corresponding
product options as standard. SCHUNK also offers customized