![SCHUNK GSP-P 08 Assembly And Operating Manual Download Page 15](http://html.mh-extra.com/html/schunk/gsp-p-08/gsp-p-08_assembly-and-operating-manual_1216080015.webp)
Assembly
02.00 | GSP-P | Assembly and Operating Manual | en | 389033
15
4 Assembly
4.1 Mechanical connection
WARNING
Risk of injury due to unexpected movements!
If the power supply is switched on or residual energy remains in
the system, components can move unexpectedly and cause
serious injuries.
•
Before starting any work on the product: Switch off the power
supply and secure against restarting.
•
Make sure, that no residual energy remains in the system.
Evenness of the
mounting surface
The values apply to the whole mounting surface to which the
product is mounted.
Requirements for evenness of the mounting surface (Dimensions in mm)
Edge length
Permissible unevenness
< 100
< 0.02
> 100
< 0.05