Assembly
5.2 Adjusting the alignment of the terminal block
WARNING
Risk of damage to the sensor!
Only align the terminal block when the sensor is switched off and
completely dry.
Terminal block
FT-AXIA130
NOTE
The standard alignment of the terminal block is position 1.
1. Remove the mounting screw (1).
2. Turn the terminal block in one of the 90° steps shown in the
illustration.
3. Apply Loctite
®
222 threadlocker to the thread of the screw (1).
4. Tighten the screw (1) with a tightening torque of 0.9 Nm.
5.3 Connections
5.3.1 Mechanical connection
Evenness of the
mounting surface
The values apply to the whole mounting surface to which the
product is mounted.
Requirements for evenness of the mounting surface (Dimensions in mm)
Edge length
Permissible unevenness
< 100
< 0.02
> 100
< 0.05
27