Assembly
11.00 | EZN | Assembly and Operating Manual | en | 389068
27
Both variants
■
Logic and motor voltage are disconnected from the controller.
■
The intermediate circuit voltage has dropped to a residual
voltage of less than 10 V.
Ø
Check the flatness of the mounting surface,
Ø
Screw the product to the machine/system,
✓
Use suitable connecting elements (adapter plates) if necessary.
✓
Observe the permissible depth of engagement.
✓
Observe the tightening torque for the mounting screws.
Ø
Connect the ground cable between the product and the
machine/system,
Variant with
hybrid cable
Ø
Connect the connection cable,
Electrical connection to the ECM controller
✓
Encoder connection cable on the controller to the "Resolver"
terminal strip.
✓
Power connection cable on the controller to the "Motor"
terminal strip.
Variant with
Y-plug
Ø
Plug encoder and power connection cables into the Y-plug and
screw in.
Ø
Connect the connection cable,
Electrical connection to the ECM controller
✓
Encoder connection cable on the controller to the "Resolver"
terminal strip.
✓
Power connection cable on the controller to the "Motor"
terminal strip.
Ø
Fasten the connection plug to the machine/system via the
assembly bores.
✓
IMPORTANT! The cable between gripper and Y-plug may
not be subjected to any mechanical load.
Both variants
Ø
Protect the power circuit of the controller,
Variant
dust-tight (SD)
Ø