5.1.1.3 Changing the position of the connection cable
NOTICE
Risk of damage to the contacts!
The contacts can be damaged if the valve cover is screwed on
firmly and the alignment of the connection cable changed.
•
Define the position of the connection cable when the valve
cover is put on.
Valve cover
Ø
Unscrew the knurled nut (1) of the valve cover (3) from the
valve cartridge (2).
Ø
Remove the valve cover (3) from the valve cartridge (2).
Ø
Put on the valve cover (3) again with the connection cable in the
required alignment and hold it in position.
Ø
Tighten the valve cover (3) on the valve cartridge (2) with the
knurled nut (1).