Item Mounting
DPG-plus
160
200
240
300
380
Side A
1
Mounting screw
M8
M10
M12
M16
M20
Max. depth of
engagement from
locating surface [mm]
20
20
25.5
31
32
2
Centering sleeve
Ø 12
Ø 14
Ø 16
Ø 22
Ø 28
Side B
4
Bore for mounting
screws
M6
M8
M10
M12
M16
2
Centering sleeve
Ø 12
Ø 14
Ø 16
Ø 22
Ø 28
Side C
5
Bore for mounting
screws
M8
M10
M12
M16
M20
3
Centering sleeve
Ø 12
Ø 14
Ø 16
Ø 22
Ø 28
5.2.2 Pneumatic connection
NOTE
• Observe the requirements for the compressed air supply,
• In case of compressed air loss (cutting off the energy line), the
components lose their dynamic effects and do not remain in a
secure position. However, the use of a SDV-P pressure
maintenance valve is recommended in this case in order to
maintain the dynamic effect for some time. Product variants
are also offered with mechanical gripping force via springs,
which also ensure a minimum clamping force in the event of a
pressure drop.
• Open only the air connections that are needed.
• Close unused main air connections using the screw plugs from
the enclosed pack.
• For a hose-free direction connection, use the O-rings from the
enclosed pack.