Fundamental Safety Instructions
8
01 | Matrix-Plate SMPL | Assembly- and Operating Manual | en-US | 0489081
CAUTION
Noise pollution caused by exhaust air or leakage during
operation
Hearing damage
•
In the event of leakage, check connections and lines and
remedy leakages
•
Wear ear protectors.
2.4 Environmental and Operating Conditions
The Matrix-Plate must not be operated under the following
conditions:
• In potentially explosive atmospheres
• Use in an environment with acidic or alkaline media
The Matrix-Plate is installed with a separate vacuum supply on a
machine tool or machining center.
NOTE
To ensure that the workpiece is securely held on the clamping
plate, you must check the vacuum level directly on the clamping
device.
DANGER
Flying workpiece due to insufficient clamping force during
machining, resulting from insufficient vacuum or excessive
machining forces.
Risk of injury or death due to flying workpiece
•
Monitor the vacuum value as close to the clamping location as
possible.
•
Wear personal protective clothing.
•
If in doubt, consult SCHUNK before the start of operations.
2.5 Personnel Qualifications
Unqualified personnel cannot recognize dangers and are therefore
exposed to higher risks!
The operating company must ensure the following points:
• The personnel must be commissioned for the activities
described in these operating instructions.