Maintenance
02.00|ROTA NC plus 2 / ROTA NCF plus 2 |en
39
(For product information about LINO MAX, see the "Accessories"
chapter of the SCHUNK lathe chuck catalog or contact SCHUNK.)
CAUTION
Allergic reactions due to grease in contact with skin!
Wear gloves.
Maintenance intervals
Lubrication of the grease areas:
Lubrication interval Strain
every 25 hours
normal / coolant utilization
every 8 hours
high / coolant utilization
after 1200 hours or
as needed
Total cleaning with disassembly of the
chuck, depending on type and degree of
contamination
Changing the top jaws
When changing the top jaws, the serration has to be cleaned and
greased with SCHUNK LINOMAX special grease.
9.2
9.3