Assembly and installation
24
02.00 | PW V6 | Assembly and operating manual | en | 389670
5.2 Electrical connection
DANGER
Danger from electric voltage!
Touching live parts may result in death.
•
Switch off the power supply before any assembly, adjustment
or maintenance work and secure against being switched on
again.
•
Only qualified electricians may perform electrical installations.
•
Check if de-energized, ground it and hot-wire.
•
Cover live parts.
NOTICE
Risk of damage to the electronics!
A faulty connection can cause damage to the internal electronics.
•
The supply network must be a network of type "PELV" for
power and logic.
•
Observe the PIN assignment of the connecting terminals.
•
Make sure that all components are grounded correctly.
NOTICE
Damage through regenerative energy!
Regenerative energy may build up under great loads. This can
damage the electronics.
•
Ensure discharge of regenerative energy on customer's
premises.
SCHUNK recommends the use of a brake chopper
(Type: ACC3EA001 ID number 9951504). The response
threshold of the utilized brake chopper must be set as follows:
For 24 V operation:
set the brake chopper to 28 V or "0"
NOTE
The cable color throughout this chapter refers to the use of a
SCHUNK connection cable.