background image

• 4 •

3.  FEATURES

1. 

Battery clamps

2. 

Micro-USB charging port

3. 

Ready/Fail LED

4. 

Battery status/Light button

5. 

Battery status indicators

6. 

Built-in work light

7. 

ON/OFF Power switch

8. 

USB port

9. 

Air compressor ON/OFF switch

10. 

Air compressor gauge

11. 

Air compressor hose wrap cleats 

12. 

Air compressor hose

13. 

Air compressor adapters and storage bag

14. 

Micro/USB charging cable

1

2

3

4

5

6

7

8

11

9

13

12

14

10

4.  CHARGING THE INTERNAL BATTERY OF THE JUMP STARTER

IMPORTANT: 

CHARGE IMMEDIATELY AFTER PURCHASE, AFTER EACH USE AND EVERY 30 DAYS, TO KEEP THE JUMP STARTER’S INTERNAL BATTERY FULLY 

CHARGED AND PROLONG BATTERY LIFE.

4.1 

CHECKING THE LEVEL OF THE INTERNAL BATTERY

Press the 

ON/OFF Power switch, and then press the 

Battery Status/Light

 button on the front of the unit. The LEDs will indicate the current charge level as follows:

Red LED flashing:

 0-5% of full charge; immediately charge the unit. 

Red LED solid:

 6-49% of full charge. 

Yellow LED solid:

 50-75% of full charge. 

Green LED solid:

 76-100% of full charge. 

4.2 

CHARGING THE INTERNAL BATTERY

The jump starter will fully charge in 3-4 hours. 

NOTE: 

Use a 2A USB charger (not included), or a 2A USB charging port to quickly recharge the jump starter. Using a charger with less than 2A will increase charge time. 

1. 

Plug the Micro USB end of a charging cable into the input port. Next, plug the USB end of the charging cable into your charger’s USB port. 

2. 

Plug your charger into a live power source.

3. 

When the unit is charging, the three LEDs will flash as follows:

Red LED flashing:

 0-49%

Red LED solid and Yellow LED flashing:

 50-75% 

Red and Yellow LEDs solid and Green LED flashing:

 76-99% 

Green LED solid:

 100% 

4. 

Ten seconds after the battery has reached full charge, the green LED will turn solid.

5. 

If the Red 

Ready/Fail 

LED lights and the buzzer sounds, the unit’s protection has been activated (such as short circuit protection, battery low voltage protection, reverse 

polarity protection, etc.) and the unit will not operate.

6. 

When the battery is fully charged, disconnect your charger from the power source and then remove the charging cable from the charger and   the unit. Make sure the 

power switch is set to OFF, if not using the jump starter immediately.

5.  OPERATING INSTRUCTIONS

5.1 

JUMP STARTING A VEHICLE
IMPORTANT: 

Using the jump starter without a battery installed in the vehicle will damage the vehicle’s electrical system.

1. 

Turn the ignition OFF.

2. 

Lay the DC cables away from any fan blades, belts, pulleys and other moving parts.

3. 

For a negative-ground vehicle (as in most vehicles), connect the jump starter’s POSITIVE (RED) clamp to the POSITIVE (POS, P, +) battery post. Next, connect the 

NEGATIVE (BLACK) clamp to the vehicle chassis or engine block, away from the battery. 

4. 

For a positive-ground vehicle, connect the jump starter’s NEGATIVE (BLACK) clamp to the NEGATIVE (NEG, N, -) battery post. Next, connect the POSITIVE (RED) 

clamp to the vehicle chassis or engine block away from the battery.

5. 

Press the ON/OFF switch to turn on the jump starter. The green 

Ready 

LED will light.

6. 

It is best to wait 30 seconds after clamp connection to attempt to start the vehicle. Crank for up to 5 seconds. If engine does not start, wait 30 seconds before cranking again.

7. 

After the engine starts, press the ON/OFF switch to turn the jump starter off, and then disconnect the black clamp (-) and the red clamp (+), in that order.

8. 

Recharge the unit as soon as possible after each use.

5.2 

USING THE USB PORT 

The USB port provides up to 2.4A at 5V DC.

1. 

Ensure the battery clamps are securely clipped on the storage holders.

2. 

Flip the ON/OFF power switch to turn the unit ON.

3. 

Plug your device into the USB port.

4. 

Turn on the USB device.

5. 

When finished using the USB port, flip the switch to the OFF position.

6. 

Recharge the unit as soon as possible after each use.

Summary of Contents for SL1435

Page 1: ...nual will explain how to use the jump starter safely and effectively Please read and follow these instructions and precautions carefully POR FAVOR CONSERVE ESTE MANUALDELUSUARIOYLEALOANTES DE CADAUSO En este manual le explica cómo utilizar el arrancador de manera segura y confiable Por favor lea y siga las siguientes instrucciones y precauciones ESSAYER DE GARDER LE MANUEL D INSTRUCTIONS ET LE LIR...

Page 2: ...SONAL 7 CARACTERÍSTICAS 8 PARA CARGAR LA BATERIA INTERNA DEL ARRANCADOR 8 CÓMO UTILIZAR EL ARRANCADOR 8 MANTENIMIENTO Y ALMACENAMIENTO 9 LOCALIZACIÓN Y SOLUCIÓN DE PROBLEMAS 9 REPUESTOS 10 ANTES DE DEVOLVER A REPARACIONES 10 GARANTÍA LIMITADA 10 TABLE DES MATIÈRES CONSIGNES DE SÉCURITÉ IMPORTANTES CONSERVER CES INSTRUCTIONS 11 MESURES DE SÉCURITÉ PERSONNELLE 11 CARACTÉRISTIQUES 12 CHARGEMENT DE LA...

Page 3: ... clothing when working near lead acid batteries Always have someone nearby for help 2 2 Have plenty of fresh water soap and baking soda nearby for use in case battery acid contacts your eyes skin or clothing Wash immediately with soap and water and seek medical attention 2 3 If battery acid comes in contact with eyes flush eyes immediately for a minimum 10 minutes and get medical attention 2 4 Neu...

Page 4: ...r sounds the unit s protection has been activated such as short circuit protection battery low voltage protection reverse polarity protection etc and the unit will not operate 6 When the battery is fully charged disconnect your charger from the power source and then remove the charging cable from the charger and the unit Make sure the power switch is set to OFF if not using the jump starter immedi...

Page 5: ...rned on the unit will go into Energy Saving mode after 10 minutes to prevent battery discharge Follow these steps to use any function after Energy Saving mode 1 Press the ON OFF power switch to turn the unit ON 2 The Green Ready Fail LED will light 3 After 10 minutes The USB port and Battery Status Light function will turn off 4 After 10 minutes The Green Ready Fail LED will turn off 5 Press the B...

Page 6: ...shing and buzzer sounds every second High temperature protection for unit Battery Status LED Behavior Red Yellow and Green LEDs flash at the same time High temperature protection for unit 8 REPLACEMENT PARTS Micro USB USB charging cable 3899003781Z 9 BEFORE RETURNING FOR REPAIRS For REPAIRS OR RETURNS visit 365rma com Visit batterychargers com for Replacement Parts 10 LIMITED WARRANTY For informat...

Page 7: ...de baterías de plomo ácido Siempre cuente con la presencia de otra persona para obtener ayuda 2 2 Tenga a la mano bastante agua fresca jabón y bicarbonato de sodio en caso de que el ácido de la batería entre en contacto con los ojos la piel o la ropa Lave inmediatamente con agua y jabón y busque atención médica 2 3 Si el ácido de la batería entra en contacto con los ojos enjuague inmediatamente du...

Page 8: ...erde se encenderá 5 Si el LED rojo Listo Falla se enciende y suena el zumbador se ha activado alguna protección de la unidad por ejemplo la protección de cortocircuito la protección de bajo voltaje de la batería la protección de polaridad inversa etc y la unidad no funcionará 6 Cuando la batería esté completamente cargada desconecte su cargador de la fuente de alimentación y luego retire el cable ...

Page 9: ...gía después de 10 minutos para evitar que la batería se descargue Siga estos pasos para usar cualquier función después del modo de ahorro de energía 1 Presione el interruptor de alimentación ON OFF para encender la unidad 2 El LED verde Listo Falla se iluminará 3 Después de 10 minutos el puerto USB y la función Estado de batería Luz se desactivará 4 Después de 10 minutos el LED verde Listo Falla s...

Page 10: ...l zumbador cada un segundo Protección contra alta temperatura de la unidad Comportamiento del LED de estado de batería Las luces LED rojo amarillo y verde parpadean al mismo tiempo Protección contra alta temperatura de la unidad 8 REPUESTOS Cable de carga micro USB USB 3899003781Z 9 ANTES DE DEVOLVER A REPARACIONES Para REPARACIONES O DEVOLUCIONES visite 365rma com Visite batterychargers com para ...

Page 11: ...n à proximité pour vous aider 2 2 Avoir beaucoup d eau fraîche du savon et du bicarbonate de soude pour une utilisation à proximité en cas si l acide touche vos yeux la peau ou les vêtements Laver immédiatement avec du savon et de l eau et consulter un méd ecin 2 3 Si l acide de la batterie entre en contact avec les yeux rincer les yeux immédiatement pendant 10 minutes et consulter un médecin 2 4 ...

Page 12: ...nifie que le système de protection de l unité s est activé p ex protection contre les courts circuits contre la faible tension de la batterie contre l inversion de polarité et l unité ne fonctionnera pas 6 Lorsque la batterie est entièrement chargée débranchez le chargeur de la source d alimentation puis débranchez le câble de recharge du chargeur et de l unité N oubliez pas d éteindre l unité int...

Page 13: ...sion elle passera en mode d économie d énergie après 10 minutes évitant ainsi la décharge de la batterie Suivez ces étapes pour utiliser toute fonction lorsque l unité est en mode d économie d énergie 1 Appuyez sur l interrupteur d alimentation pour activer l unité 2 Le témoin DEL vert Ready Fail Prêt Échec s allume 3 Le port USB et la fonction d état de la batterie lampe se désactiveront après 10...

Page 14: ...in DEL rouge clignotant et avertisseur sonore retentissant une fois par seconde Protection de l unité contre la surchauffe Comportement du témoin DEL d état de batterie Les témoins DEL rouge jaune et vert clignotent simultanément Protection de l unité contre la surchauffe 8 PIÈCES DE RECHANGE Câble de charge micro USB USB 3899003781Z 9 AVANT DE RETOURNER POUR LES RÉPARATIONS Pour RÉPARATION OU RET...

Reviews: