12. MAINTENANCE AND CARE

A minimal amount of care can keep your

battery charger working properly for years.

• Clean the clamps each time you are

finished charging. Wipe off any battery

fluid that may have come in contact with

the clamps to prevent corrosion.

• Occasionally cleaning the case of the

charger with a soft cloth will keep the

finish shiny and help prevent corrosion.

• Coil the input and output cords neatly

when storing the charger. This will help

prevent accidental damage to the cords

and charger.

• Store the charger unplugged from the AC

power outlet in an upright position.

• Store inside, in a cool, dry place. Do not

store the clamps clipped together, on or

around metal, or clipped to the cables.

13. TROUBLESHOOTING AND ERROR CODES

Error Codes

CODE

DESCRIPTION

REASON/SOLUTION

bAd 

bAT 

F01

The battery voltage is still under 10V 

(for a 12V battery) or 5V (for a 6V 

battery) after 2 hours of charging.

The battery could be bad. Have it checked or replaced.

SUL

The charger has detected a sulfated 

battery.

The charger will go into desulfation mode. If the 

desulfation is not successful after 10 hours, the charger 

will go into abort mode.

bAd 

bAT 

F02

The charger cannot desulfate the 

battery.

The battery could not be desulfated; have it checked or 

replaced.

bAd 

bAT

F03

The battery was unable to reach the 

“full charge” voltage.

May be caused by trying to charge a large battery or 

bank of batteries on too low of a current setting. Try 

again with a higher current setting or have the battery 

checked or replaced.

F04

The connections to the battery are 

reversed.

The battery is connected backwards. Unplug the charger 

and reverse the connections to the battery.

bAd 

bAT 

F05

The charger was unable to keep 

the battery fully charged in maintain 

mode.

The battery won’t hold a charge. May be caused by a drain 

on the battery or the battery could be bad. Make sure there 

are no loads on the battery. If there are remove them. If 

there are none, have the battery checked or replaced.

bAd 

bAT

F06

The charger detected that the battery 

may be getting too hot (thermal 

runaway). 

The charger automatically shuts the current off if it 

detects the battery may be getting too hot. Have the 

battery checked or replaced. 

If you get an error code, check the connections and settings and/or replace the battery.

Troubleshooting

PROBLEM

POSSIBLE CAUSE

SOLUTION

Battery clamps do not 

spark when touched 

together.

The charger is equipped 

with an auto-start feature. 

It will not supply current to 

the battery clamps until a 

battery is properly connected. 

The clamps will not spark if 

touched together.

No problem; this is a normal 

condition.

The charger will not 

turn on when properly 

connected.

AC outlet is dead.

Poor electrical connection.

Check for open fuse or circuit 

breaker supplying AC outlet.

Check power cord and extension 

cord for loose fitting plug.

Summary of Contents for SC1308

Page 1: ...AL AND READ BEFORE EACH USE This manual will explain how to use the battery charger safely and effectively Please read and follow these instructions and precautions carefully MODEL SC1308 Automatic Ba...

Page 2: ...THE INSTRUCTIONS EACH TIME YOU USE THE CHARGER b To reduce risk of battery explosion follow these instructions and those published by battery manufacturer and manufacturer of any equipment you intend...

Page 3: ...sition and removing AC cord from electric outlet Never allow clips to touch each other 5 2 Attach clips to battery and chassis as indicated in sections 6 and 7 6 FOLLOW THESE STEPS WHEN BATTERY IS INS...

Page 4: ...tates is not recommended and should not be used 8 3 USING AN EXTENSION CORD The use of an extension cord is not recommended If you must use an extension cord follow these guidelines Pins on plug of ex...

Page 5: ...ed VRLA valve regulated lead acid batteries Popular uses include high performance engine starting power sports deep cycle solar and storage batteries 11 OPERATING INSTRUCTIONS WARNING A spark near the...

Page 6: ...uous 12 hour period it will go into abort mode see Aborted Charge section This is usually caused by a drain on the battery or the battery could be bad MAINTAINING A BATTERY The SC1308 charges and main...

Page 7: ...ery Voltage Reading 12V Battery Voltage Reading Battery Condition 6 4 or more 12 8 or more Charged 6 1 to 6 3 12 2 to 12 7 Needs charging Less than 6 1 Less than 12 2 Discharged TESTER AND CHARGER Whe...

Page 8: ...arge voltage May be caused by trying to charge a large battery or bank of batteries on too low of a current setting Try again with a higher current setting or have the battery checked or replaced F04...

Page 9: ...and charges the battery No problem this is normal I press the display button but do not see the percentage of charge When first connected to a battery the display shows voltage only This is normal Th...

Page 10: ...0 sec max on 120 sec min off 100A int 5 sec max on 180 sec min off cUL Input 120V AC 60Hz 4A continuous 19A intermittent Output 6V 12V DC 2 6A int 25A int 60 sec max on 120 sec min off 90A int 5 sec m...

Reviews: