CHARGE/MAINTAIN MODE 

To select this mode, press the 

 

Rate 

Selection button until the yellow/orange 

6<>2A Charge/Maintain LED lights. The 

 

LED will light solid if battery is properly 

connected and the charging process will 

start. The display will show the charger 

voltage. To change the mode on the display, 

press the 

 

Display button. When the 

battery is fully charged, the green Charged/

Maintaining 

 

LED will light. If charging 

cannot be completed, the display will show 

bad

 / 

bat

” and an error code. The battery 

may be bad; have it checked.

NOTE:

 If the voltage of the battery is 

under 12.7V, the charger will automatically 

go into Boost mode, to quickly add 

energy to the battery. To abort/skip the 

temporary Boost and force the charger 

into the Charge/Maintain mode, press the 

Rate Selection button again (while still 

boosting).

AUTOMATIC CHARGING MODE

When an Automatic Charge is performed, 

the charger switches to the maintain mode 

automatically after the battery is charged. 

ABORTED CHARGE

If charging cannot be completed normally, 

charging will abort. When charging aborts, 

the charger’s output is shut off and the 

display will show “

bad

 / 

bat

” and an error 

code. Do not continue attempting to 

charge this battery. Check the battery and 

replace, if necessary.

DESULFATION MODE

The display will show “

SUL

” when a sulfated 

battery is detected, and the charger will go 

into desulfation mode. If the desulfation is 

not successful after 10 hours, the charger 

will go into abort mode. The display will 

show “

bAd

 / 

bAt

 / 

F02

”.

COMPLETION OF CHARGE

Charge completion is indicated by the 

green 

 

Charged/Maintaining LED. 

When lit, the charger has switched to the 

maintain mode of operation.  

MAINTAIN MODE  

(FLOAT MODE MONITORING)

When the green 

 

Charged/Maintaining 

LED is lit, the charger has started maintain 

mode. In this mode, the charger keeps the 

battery fully charged by delivering a small 

current when necessary. If the charger has 

to provide its maximum maintain current 

for a continuous 12 hour period, it will 

go into abort mode (see 

Aborted Charge

 

section). This is usually caused by a drain 

on the battery or the battery could be bad. 

MAINTAINING A BATTERY

The SC1308 charges and maintains both 

6V and 12V batteries.

NOTE:

 The maintain mode technology 

allows you to safely charge and maintain 

a healthy battery for extended periods of 

time. However, problems with the battery, 

electrical problems in the vehicle, improper 

connections or other unanticipated 

conditions could cause excessive current 

draws. As such, occasionally monitoring your 

battery and the charging process is required.

BATTERY CHARGING TIMES

APPLICATION

BATTERY

SIZE

CHARGING TIME (Hours)

2A    6A    8A    10A

POWERSPORTS

6Ah

6

32Ah

15

AUTOMOTIVE

300 CCA

12

1000 CCA

30

MARINE

50Ah

15

105Ah

33

2

5

4

10

5

11

1.75

4.5

3.5

8.5

4.25

9.5

1.5

4

 

3

7

3.5

8

Times are based on a 50% discharged  

battery and may change, depending on age  

and condition of battery.

 

 USING THE ENGINE START FEATURE

Your battery charger can be used to jump 

start your car if the battery is low. Follow 

all safety instructions and precautions for 

charging your battery. Wear complete eye 

protection and protective clothing. 

WARNING:

 Using the ENGINE START 

feature WITHOUT a battery installed in 

the vehicle could cause damage to the 

vehicle’s electrical system. 

NOTE: 

During extremely cold weather, or 

if the battery is under 2 volts, boost the 

battery for 5 minutes before cranking the 

engine.

NOTE:

 If you have charged the battery 

and it still will not start your car, do not 

use the Engine Start feature, or it could 

damage the vehicle’s electrical system. 

Have the battery checked.

1.

With the charger unplugged from the

AC outlet, connect the charger to the

battery following the instructions given

in 

Charging a Battery in the Vehicle

.

2.

Plug the charger AC power cord into

the AC outlet.

3.

With the charger plugged in and

connected to the battery and chassis,

select the 

 

Engine Start rate. If

the battery is properly connected, the

yellow/orange 

 

100A Engine Start

LED will light solid and the display

will show “

ON

”. If display shows “

0

.

0

”,

check the battery connections. If the

display does not show “

On

”, check the

Summary of Contents for SC1308

Page 1: ...AL AND READ BEFORE EACH USE This manual will explain how to use the battery charger safely and effectively Please read and follow these instructions and precautions carefully MODEL SC1308 Automatic Ba...

Page 2: ...THE INSTRUCTIONS EACH TIME YOU USE THE CHARGER b To reduce risk of battery explosion follow these instructions and those published by battery manufacturer and manufacturer of any equipment you intend...

Page 3: ...sition and removing AC cord from electric outlet Never allow clips to touch each other 5 2 Attach clips to battery and chassis as indicated in sections 6 and 7 6 FOLLOW THESE STEPS WHEN BATTERY IS INS...

Page 4: ...tates is not recommended and should not be used 8 3 USING AN EXTENSION CORD The use of an extension cord is not recommended If you must use an extension cord follow these guidelines Pins on plug of ex...

Page 5: ...ed VRLA valve regulated lead acid batteries Popular uses include high performance engine starting power sports deep cycle solar and storage batteries 11 OPERATING INSTRUCTIONS WARNING A spark near the...

Page 6: ...uous 12 hour period it will go into abort mode see Aborted Charge section This is usually caused by a drain on the battery or the battery could be bad MAINTAINING A BATTERY The SC1308 charges and main...

Page 7: ...ery Voltage Reading 12V Battery Voltage Reading Battery Condition 6 4 or more 12 8 or more Charged 6 1 to 6 3 12 2 to 12 7 Needs charging Less than 6 1 Less than 12 2 Discharged TESTER AND CHARGER Whe...

Page 8: ...arge voltage May be caused by trying to charge a large battery or bank of batteries on too low of a current setting Try again with a higher current setting or have the battery checked or replaced F04...

Page 9: ...and charges the battery No problem this is normal I press the display button but do not see the percentage of charge When first connected to a battery the display shows voltage only This is normal Th...

Page 10: ...0 sec max on 120 sec min off 100A int 5 sec max on 180 sec min off cUL Input 120V AC 60Hz 4A continuous 19A intermittent Output 6V 12V DC 2 6A int 25A int 60 sec max on 120 sec min off 90A int 5 sec m...

Reviews: