Schumacher ProSeries 00-99-000742 Owner'S Manual Download Page 8

7

USING YOUR BATTERY CHARGER

OVERVIEW

Using this battery charger is very simple. 

First, connect the battery and AC power 

following  the  precautions  listed  under 

“OPERATING INSTRUCTIONS”. Then se-

lect the appropriate BATTERY TYPE and 

charge rate for your battery. The charger 

will then do everything automatically. This 

section explains a few details.

CHARGING: 

If  the  charger  does  not 

detect  a  properly  connected  battery, 

the  CONNECTED  (yellow)  LED  will  not 

light. Charging will not begin unless the 

CONNECTED LED is on. When charging 

begins, the CHARGING LED will be lit.

AUTOMATIC  SHUT  OFF:

  When  the 

SMALL  BATTERY  or  REGULAR  BAT-

TERY  charge  is  selected,  the  charger 

is  set  to  perform  an  automatic  charge. 

When an automatic charge is performed, 

the charger stops charging automatically 

after the battery is charged. 

ABORTED  CHARGE: 

If  charging  can’t 

be completed normally, charging will be 

aborted.  When  charging  is  aborted,  the 

charger’s output is shut off and the digital 

display blinks on and off. In that state, the 

charger ignores all buttons. To reset from 

after an aborted charge, either disconnect 

the battery or unplug the charger.

DESULFATION  MODE:

  If  a  battery  is 

left  discharged  for  an  extended  period, 

it could become sulfated and not accept 

a normal charge. If the charger detects a 

sulfated battery, the charger will switch to 

a special mode of operation designed for 

such  batteries.  Activation  of  the  special 

desulfation mode is indicated by blinking 

the CHARGING LED. If successful, nor-

mal charging will resume after the battery 

is desulfated. The CHARGING LED will 

then stop blinking and light continuously. 

Desulfation could take up to 10 hours. If 

desulfation fails, charging will be aborted 

and the digital display will blink. 

C O M PL E T I O N   O F   C H A RG I N G:

 

Charge  completion  is  indicated  by 

the  CHARGED  (green)  LED;  when 

lit,  the  charger  has  stopped  charging 

and  switched  to  the  Maintain  Mode  of  

operation, if the DEEP CYCLE battery type 

was selected. For other battery types, the 

CHARGED LED comes on when the bat-

tery is charged enough for normal use.

MAINTAIN MODE

: When the CHARGED 

(green) LED is lit, the charger has started 

Maintain Mode. This mode of operation is 

also known as Float-Mode Monitoring. In 

this mode, the charger keeps the battery 

fully charged by delivering a small amount 

of current, when necessary. The voltage 

is maintained at a level determined by the 

BATTERY TYPE selected.

NOTE:

 For battery types other than DEEP 

CYCLE, the charged LED might be lit be-

fore Maintain Mode is started.

GENERAL CHARGING NOTES:

The  charger  is  designed  to  control  its 

cooling  fan  for  efficient  operation.  Con

-

sequently, it is normal for the fan to start 

and stop when maintaining a fully charged 

battery.  The  fan  does  not  run  in  Tester 

Mode.
If the charge mode is changed after charg-

ing has started (by pressing the CHARGE 

START or BATTERY TYPE button), the 

charging process will be restarted. 
The  voltage  displayed  during  charging 

will  usually  be  higher  than  the  battery’s 

resting voltage.
The voltage displayed during charging is 

the battery voltage, not the RMS charg-

ing voltage.

Summary of Contents for ProSeries 00-99-000742

Page 1: ...S MANUAL Schumacher Electric Corporation Professional Products Division Mount Prospect IL 60056 U S A Model PSC 12500A For 6 and 12 Volt Batteries Send Warranty Product Repairs to Customer Service Re...

Page 2: ...arefully IMPORTANT SAFETY INSTRUCTIONS 2 PERSONAL SAFETY PRECAUTIONS 3 BEFORE USING YOUR BATTERY CHARGER 3 Plugging It In 3 Assembling Your Charger 3 Using An Extension Cord 4 PREPARING YOUR BATTERY T...

Page 3: ...LOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY save these Ins...

Page 4: ...tely get medical attention Remove all personal metal items from your body such as rings bracelets necklaces and watches while working with a lead acid battery A battery can produce a short circuit cur...

Page 5: ...e boat battery installed in a boat must be removed and charged on shore Using an extension cord The use of an extension cord is not rec ommended If you must use an extension cord please make sure that...

Page 6: ...onds the CHARGING yellow LED should light and the charging process should start 8 To disconnect the charger unplug its powercordbeforeattemptingtodiscon nect the output clamps Then standing 1 Note the...

Page 7: ...ery 4 Clean and store the charger in a dry location Note During the starting sequence listed above the charger is set to one of three states 1 Wait for cranking The charger waits until the engine is a...

Page 8: ...y blinking the CHARGING LED If successful nor mal charging will resume after the battery is desulfated The CHARGING LED will then stop blinking and light continuously Desulfation could take up to 10 h...

Page 9: ...les The6V REGULAR batterytypeisnotselectableforbatteries greater than 8 5V DC With the exception of AGM and gel cell batteries all other battery types may or may not have vent caps Vent caps are locat...

Page 10: ...O 85 130 Alternator tester on bad alternator O O 0 84 131 199 Small Battery 2A charge activated O O O xx or xx x V Regular Battery 15A 40A charge activated O O O xx or xx x V Charge complete Maintain...

Page 11: ...tester to charger if a battery is connected In that case the charger will be set for the small battery charge rate and 12V regular battery type TESTER WITHOUT TIME LIMIT If either the DIGITAL Display...

Page 12: ...the digital display button to set the tester to Al ternator and read the alternator percent using the built in alternator tester TESTER STATUS LEDs When the PSC 12500A is operating as an alternator te...

Page 13: ...arge rate if it is determined that the battery can accept the 40A rate All charging modes will decrease the charge rate as the battery approaches maximum charge After the charging process has started...

Page 14: ...ur vehicle you don t need to wait for the entire charging process to be completed When the charger displays a battery of 77 or more see page 12 the battery has usually been charged enough for the vehi...

Page 15: ...hours May be due to a very large battery or a bank of batter ies requiring more power than a 15 40 amp charger can deliver within 24 hours The battery may also be faulty Reset the charger by briefly u...

Page 16: ...er or its authorized representative The manufacturer makes no warranty other than this limited warranty and expressly excludes any implied warranty including any warranty for consequential damages THI...

Reviews: