Schumacher ProSeries 00-99-000742 Owner'S Manual Download Page 15

14

TROUBLESHOOTING

Performance problems often can be corrected by the user. Please read through this chart 

for a possible solution to common problems.

PROBLEM

POSSIBLE CAUSE

SOLUTION

The battery is connected 

and the charger is on, 

but isn't charging.

The charger is in tester 

mode, not charger mode.

Press the CHARGE 

START button to activate 

charging and select a 

charge rate.

Indicator lights are lit in 

an erratic manner not 

explained in the “Using 

Your Battery Charger” 

section.

You might have acciden-

tally activated a special 

diagnostic mode.

The charger may be 

defective.

Make sure nothing is 

touching the control 

panel, then unplug the 

charger and plug it in 

again.
Return to place of pur-

chase for replacement. 

The DIGITAL DISPLAY 

always flashes before 

the battery is completely 

charged.

The incorrect BATTERY 

TYPE may have been 

selected. 

This will happen if the 

battery did not reach full 

charge within 24 hours. 

May be due to a very large 

battery or a bank of batter-

ies requiring more power 

than a 15



40 amp 

charger can deliver within 

24 hours. The battery may 

also be faulty.

Reset the charger by 

briefly unplugging it or 

briefly disconnecting the 

negative battery clip. Se-

lect the desired charge 

rate (SMALL or REGU-

LAR BATTERY) and 

BATTERY TYPE again, if 

necessary.

Engine crank time is less 

than specified. 

Starter motor may be 

drawing more than 125 

amps.

Charge the battery at the 

REGULAR BATTERY 

rate for 10 to 15 minutes 

then crank the engine.

The green CHARGED 

LED lights a few minutes 

after connecting to the 

battery.

The battery may be 

fully charged or recently 

charged, leaving the bat-

tery voltage high enough 

to appear to be fully 

charged.
The incorrect BATTERY 

TYPE may have been 

selected.

If the battery is in a ve-

hicle, turn the headlights 

on for a few minutes 

to reduce the battery 

voltage and try charging 

again.
Reset the charger by 

briefly unplugging it or 

briefly disconnecting the 

negative battery clip. 

Select the desired charge 

rate (SMALL or REGU-

LAR BATTERY) and 

BATTERY TYPE again, if 

necessary.

Summary of Contents for ProSeries 00-99-000742

Page 1: ...S MANUAL Schumacher Electric Corporation Professional Products Division Mount Prospect IL 60056 U S A Model PSC 12500A For 6 and 12 Volt Batteries Send Warranty Product Repairs to Customer Service Re...

Page 2: ...arefully IMPORTANT SAFETY INSTRUCTIONS 2 PERSONAL SAFETY PRECAUTIONS 3 BEFORE USING YOUR BATTERY CHARGER 3 Plugging It In 3 Assembling Your Charger 3 Using An Extension Cord 4 PREPARING YOUR BATTERY T...

Page 3: ...LOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY save these Ins...

Page 4: ...tely get medical attention Remove all personal metal items from your body such as rings bracelets necklaces and watches while working with a lead acid battery A battery can produce a short circuit cur...

Page 5: ...e boat battery installed in a boat must be removed and charged on shore Using an extension cord The use of an extension cord is not rec ommended If you must use an extension cord please make sure that...

Page 6: ...onds the CHARGING yellow LED should light and the charging process should start 8 To disconnect the charger unplug its powercordbeforeattemptingtodiscon nect the output clamps Then standing 1 Note the...

Page 7: ...ery 4 Clean and store the charger in a dry location Note During the starting sequence listed above the charger is set to one of three states 1 Wait for cranking The charger waits until the engine is a...

Page 8: ...y blinking the CHARGING LED If successful nor mal charging will resume after the battery is desulfated The CHARGING LED will then stop blinking and light continuously Desulfation could take up to 10 h...

Page 9: ...les The6V REGULAR batterytypeisnotselectableforbatteries greater than 8 5V DC With the exception of AGM and gel cell batteries all other battery types may or may not have vent caps Vent caps are locat...

Page 10: ...O 85 130 Alternator tester on bad alternator O O 0 84 131 199 Small Battery 2A charge activated O O O xx or xx x V Regular Battery 15A 40A charge activated O O O xx or xx x V Charge complete Maintain...

Page 11: ...tester to charger if a battery is connected In that case the charger will be set for the small battery charge rate and 12V regular battery type TESTER WITHOUT TIME LIMIT If either the DIGITAL Display...

Page 12: ...the digital display button to set the tester to Al ternator and read the alternator percent using the built in alternator tester TESTER STATUS LEDs When the PSC 12500A is operating as an alternator te...

Page 13: ...arge rate if it is determined that the battery can accept the 40A rate All charging modes will decrease the charge rate as the battery approaches maximum charge After the charging process has started...

Page 14: ...ur vehicle you don t need to wait for the entire charging process to be completed When the charger displays a battery of 77 or more see page 12 the battery has usually been charged enough for the vehi...

Page 15: ...hours May be due to a very large battery or a bank of batter ies requiring more power than a 15 40 amp charger can deliver within 24 hours The battery may also be faulty Reset the charger by briefly u...

Page 16: ...er or its authorized representative The manufacturer makes no warranty other than this limited warranty and expressly excludes any implied warranty including any warranty for consequential damages THI...

Reviews: