Schumacher MCF-1 Owner'S Manual Download Page 6

6

Sch555 English 10/30/97

K.

BATTERY CHARGING

O.

CHARGER LOCATION PRECAUTIONS

N.

ENGINE START

M.

INDICATIONS OF A FULLY CHARGED BATTERY

L.

CHARGE PERIOD

1. Before charging any battery, make sure the electrolyte (battery fluid) in each cell is at correct  level. This is not required on

maintenance free batteries. Read instructions on battery.

2. Set switches and or timers to Off, if the position is available. If no Off position is on your charger  set in the lowest charge rate

featured ( 1 amp MCF1, 2 amp on others}.

3. If the battery is being charged inside the vehicle, use connection procedures outlined in Section  E. Should the battery be removed

from the vehicle, follow the instructions in Section D (step 6) and  Section F. Plug the power cord into the AC outlet.

4. Set the power switch from Off (or the lowest charge rate) to the desired charge position. NOTE:  This charger is a MANUAL type

charger and the charging must be monitored closely to prevent  overcharging of the battery.

The approximate time required to bring a battery to a full charge state depends upon the number of  ampere hours (AH’s!
depleted from the battery. AH’s are determined by multiplying the number of  hours time the number of amps supplied by the
battery to the load For example- If a load was  connected to battery which drew 7 amperes for a period of five hours, the battery
will have supplied  35 AH. The approximate recharge time would be calculated by dividing 35 AH depleted from the  battery, by
the ampere charge rate of the charger .To allow for tapering of the charge rate add 25%  to the charge time.

A hydrometer reading of the specific gravity of the electrolyte (fluid) of a battery in good condition  should be between 1.25 and 1.285.
When a battery reaches 80-85% of full charge, bubbles will  appear on the surface of the fluid As the battery nears full charge, bubbling
will become more  vigorous.

When the Meter reaches about 1/2 the charge rate. ( See Meter Functions) The MCF 1 does not  have a meter.

1. Connect the charger to the battery following instructions given in Section K.

2. Set charger to Off  position, (on SF 1052 set at the 2 amp position).

3. Plug power cord into AC outlet, then move switch from Off to Engine Start. On SF 1052 move from 2 amp to Engine Start.

4. During extremely cold weather, or if the battery is fairly exhausted, charge the battery for a few  minutes before you attempt the

Engine Start.

5. Crank the engine by turning the ignition key.

6. If the engine fails to start, let the battery charge for another/few minutes then, try the engine start  again.

Never place the charger directly above battery being charged, gases from battery could damage the  charger.

Never allow the battery acid to drip on charger when reading specific gravity or filling battery.

Do Not operate the charger in a closed in area or restrict ventilation in any way. Keep off from  carpets, seats, etc.

Do Not set the battery on top of the charger.

SCHUMACHER ELECTRIC CORPORATION, 801 BUSINESS CENTER DRIVE, MOUNT
PROSPECT, ILLINOIS, 60056-2179 MAKES THIS LIMITED WARRANTY TO THE ORIGI-
NAL PURCHASER AT RETAIL OF THIS PRODUCT. THIS LIMITED WARRANTY IS NOT
TRANSFERABLE.

Schumacher Electric Corporation warrants this battery charger for 2 years from date of
purchse at retail against defective material or workmanship. If such should occur, the unit
will be repaired or replaced at the option of the manufacturer. It is the obligation of the
purchaser to forward the unit together with proof of purchase, transportation and / or
mailing charges prepaid to the manufacturer or its authorized representative. This limited
warranty is void if the product is misused, subjected to careless handling, or repaired by
anyone other than the factory or other authorized factory representative. The manufac-

turer makes no warranty other than this limited warranty and expressly excludes any
implied warranty including any warranty for consequential damages.

This is the only express limited warranty and the manufacturer neither assumes nor autho-
rizes anyone to assume or make any other obligation towards the product other than this
express limited warranty. The manufacturer makes no warranty of merchantability or fitness
for purpose of this product and expressly excludes such from this limited warranty. Some
states do not allow the exclusion or limitation of incidental or consequential damages or
length of implied warranty so the above limitations or exclusions may not apply to you.
“This warranty gives you specific legal rights, and you may have other rights which vary
from state to state.”

LIMITED WARRANTY

Summary of Contents for MCF-1

Page 1: ...lt in fire or electric shock If an extension cord must be used make sure that Pins on plug of extension cord are the same number size and shape as those of plug on charger Extension cord is properly w...

Page 2: ...ile working with a battery Acid particles corrosion may get into your eyes If acid enters your eye immediately flood eye with running cold water for at least 10 minutes Get medical attention immediate...

Page 3: ...rger 1 Check polarity of battery posts Battery case will be marked by each post POSITIVE POS P and NEGATIVE NEG N NOTE The positive battery post usually has a larger diameter than the negative post 2...

Page 4: ...ATTERY TESTER Model SF 60 only 1 Since this test is based on terminal voltage of the battery always begin with fully charged battery The Battery must be in the vehicle with the engine and accessories...

Page 5: ...the HOLD position is selected the charger will remain on indefinitely Familiarize yourself with the action of these settings by rotating the knob through each position several times J BATTERY TYPES T...

Page 6: ...Engine Start On SF 1052 move from 2 amp to Engine Start 4 During extremely cold weather or if the battery is fairly exhausted charge the battery for a few minutes before you attempt the Engine Start 5...

Page 7: ...une rallonge moins que ce soit absolument n cessaire L utilisation d une rallonge inad quate risque d occasionner un incendie ou des chocs lectriques Si vous devez vous servir d une rallonge assurez...

Page 8: ...prise par un lectricien qualifi Une mauvaise connexion risque d occasionner des chocs lectriques DANGER Avant d utiliser un adaptateur comme le montre l illustration assurez vous que la vis centrale d...

Page 9: ...terie Pour r duire les risques d tincelle pr s de la batterie respectez les consignes de s curit suivantes lorsque la batterie est hors du v hicule ATTENTION Une tincelle pr s de la batterie peut prov...

Page 10: ...rg e lorsque l aiguille de l amp rem tre est pr s de la ligne pointill e comme le montre l illustration droite ce qui est environ la moiti de l intensit de charge choisie environ 4 5 amp res pour un r...

Page 11: ...la position ARR T le chargeur se fermera Lorsqu on choisit la position ATTENTE le chargeur reste en marche ind finiment Familiarisez vous avec la fa on dont le chargeur fonctionne selon chacun des r...

Page 12: ...passer l interrupteur de courant de la position Arr t ou de la plus basse intensit de charge la position de charge d sir e REMARQUE Ce chargeur est de type MANUEL et la charge doit tre troitement sur...

Reviews: