• 14 •
PROBLEM
POSSIBLE CAUSE
SOLUTION
Short or no start cycle when
cranking engine.
No power at receptacle.
AC cord and/or extension cord is
loose.
The clamps are not making a
good connection.
Failure to wait 3 minutes between
cranks.
The battery may be severely
discharged.
The battery is drawing more than
the engine start rate.
The charger may be overheated.
Check for open fuse or circuit breaker
supplying AC outlet.
Check power cord and extension cord
for loose fitting plug.
Check for poor connection at battery
and frame.
Wait 3 minutes of rest time before the
next crank.
On a severely discharged battery, use
the Boost rate for 10 to 15 minutes, to
assist in cranking.
Crank time varies with the amount of
current drawn. If cranking draws more
than the engine start rate, crank time
may be less than 5 seconds.
The thermal protector may have
tripped and needs a little longer to
reset. Make sure the charger vents
are not blocked. Wait and try again.