background image

• 5 •

6. 

Crank the engine for no more than  

8 seconds. If the engine does not start, 

wait 2 minutes before cranking again.

7. 

After the engine starts, turn the switch 

to the OFF position and remove the 

Instant Power from the battery.

8. 

Charge the Instant Power.

USING THE USB PORT 

(Model XP750C)

The USB port provides up to 2A  

at 5V DC.

1. 

Ensure the battery clamps are 

securely clipped on the storage 

holders.

2. 

Turn the Instant Power ON.

3. 

Plug your device into the USB port.

4. 

When finished using the USB port, 

turn the switch to the OFF position.

5. 

Charge the Instant Power.

USING THE WORK LIGHT

The work light is controlled by a sliding 

ON/OFF switch located on the front of 

the Instant Power. Make sure the lamp 

is turned OFF when the unit is being 

recharged or stored. 

Position the Instant Power on a flat, stable 

surface near the intended work area.

Ensure the battery clamps are securely 

clipped on the storage holders.

POWERING A 12V DC DEVICE

The Instant Power is a power source for 

all 12V DC accessories that are equipped 

with a 12V accessory plug. Use it for power 

outages and on fishing or camping trips.

NOTE:

 Do not power a 12V device with 

the Instant Power while charging the 

internal battery. 

1. 

Make sure the device to be powered 

is OFF before inserting the 12V DC 

accessory plug into the 12V DC 

accessory outlet.

2. 

Open the protective cover of the DC 

power outlet on the Instant Power. 

3. 

Plug the 12V DC device into the DC 

power outlet and turn on the 12V DC 

device (if required).

4. 

When finished, turn off the DC device  

(if required) and unplug from the DC 

power outlet.

CAUTION:

 Do not use the Instant Power  

to run appliances that draw more than  

15A DC.

NOTE: 

Extended operation of a 12V DC 

device may result in excessive battery 

drain. Recharge the Instant Power 

immediately after unplugging the 12V  

DC device.

Estimated run-times

 

APPLIANCE 

TYPE

EST 

WATTAGE

XP400

XP750C

Cell phone

4 watts

13 hrs

34 hrs

Fluorescent 

light

4 watts

15 hrs

34 hrs

Radios, fans

9 watts

6.7 hrs

14 hrs

Depth finder

9 watts

6.7 hrs

14 hrs

Camcorder

15 watts

4 hrs

7 hrs

Electrical tool

24 watts

2.5 hrs

5 hrs

Electric cooler 48 watts

1.3 hrs

2 hours

Car vacuum,  

air compressor

80 watts

0.8 hrs

1.8 hrs

NOTE:

 Actual time may vary. Times are based  

on the internal battery being fully charged.

USING THE AIR COMPRESSOR 

(Model XP750C) 

WARNING. 

Read the instructions of the 

product being inflated before using the 

compressor. Avoid overinflation; do not 

exceed the manufacturer’s recommended 

pressures. Do not leave the air 

compressor unattended during use.

NOTE:

 Wrap cleats are provided for 

convenient storage of the air compressor 

hose. Wrap the hose around these cleats 

when the hose is not in use.

1. 

Remove the air compressor hose from 

the storage cleats.

2. 

Connect the adaptor to the valve 

stem and close the thumb latch. If 

necessary, use one of the additional 

adaptors. 

3. 

Press the air compressor power 

switch to turn ON and inflate to the 

desired pressure or fullness (refer to 

the gauge next to the switch). 

4. 

When the desired pressure is 

reached, press the air compressor 

power switch to turn OFF, open the 

thumb latch and remove the connector 

from the valve stem.

5. 

Allow unit to cool.

6. 

Recharge the unit before storing.

NOTE:

 The air compressor is rated for  

150 PSI.

Estimated time for inflating

Vehicle tires 13-16"

6-24 minutes

Bike tires

1-3 minutes

Sports balls

30 seconds

These times are approximate. Use the air  

compressor gauge to ensure the proper  

pressure has been reached. Do not overinflate.

Summary of Contents for INSTANT POWER XP400

Page 1: ...ND READ BEFORE EACH USE This manual will explain how to use the Instant Power safely and effectively Please read and follow these instructions and precautions carefully POR FAVOR GUARDE ESTE MANUAL DE...

Page 2: ...ssional if service or repair is required Incorrect assembly may result in fire or electrical shock Do not use the Instant Power to jump a vehicle while charging the internal battery Do not recharge th...

Page 3: ...s bracelets necklaces and watches A battery can produce a short circuit current high enough to weld a ring to metal causing a severe burn Never smoke or allow a spark or flame in the vicinity of the b...

Page 4: ...INTERNAL BATTERY FOR MORE THAN 30 MINUTES OR LEAVE THE BATTERY UNATTENDED IT COULD EXPLODE CAUSING PROPERTY DAMAGE OR PERSONAL INJURY 1 Make sure the car is running 2 Insert one end of the accessory...

Page 5: ...more than 15A DC NOTE Extended operation of a 12V DC device may result in excessive battery drain Recharge the Instant Power immediately after unplugging the 12V DC device Estimated run times APPLIAN...

Page 6: ...position The Instant Power won t power my 12V device The 12V device is not turned on The Instant Power s battery is not charged The 12V device draws more than 15A or has a short circuit Turn on the 1...

Page 7: ...uct that are not manufactured by Schumacher Electric Corporation and approved for use with this product This Limited Warranty is void if the product is misused subjected to careless handling repaired...

Page 8: ...exponga el Instant Power a la lluvia o la nieve Nunca coloque el Instant Power directamente sobre la bater a que se est cargando Para evitar la formaci n de arcos el ctricos nunca permita que las pin...

Page 9: ...erruptor de APAGADO ENCENDIDO para el compresor de aire 11 Puerto interno del cargador de bater a 12 Sujetador para la manguera del compresor de aire 13 Manguera del compresor de aire 14 Adaptadores d...

Page 10: ...t n Estado de la bater a en la parte frontal de la unidad Cuando la bater a esta completamente cargada primero desconecte el cable auxiliar del Instant Power y luego de la toma del encendedor del veh...

Page 11: ...e 12V CC Tiempo estimado de funcionamiento TIPO DE DISPOSITIVO POTENCIA APROX XP400 XP750C Tel fono celular 4 vatios 13 hrs 34 hrs Luz fluorescente 4 vatios 15 hrs 34 hrs Radios ventiladores 9 vatios...

Page 12: ...nte de poder y coloque las pinzas en forma correcta Verifique la condici n de carga de la bater a girando el interruptor situado enfrente de la fuente de poder Consulte la secci n de Indicadores LED e...

Page 13: ...liente al 1 800 621 5485 NO ENV E LA UNIDAD hasta que usted reciba AUTORIZACI N DE DEVOLUCI N DE MERCANC A RMA de Servicios al Cliente de Schumacher Electric Corporation 9 ESPECIFICACIONES XP400 Tipo...

Page 14: ...an el Fabricante o si esta unidad es revendida a trav s de un vendedor minorista no autorizado El Fabricante no realiza ninguna otra garant a incluidas a t tulo enunciativo las garant as expresas impl...

Page 15: ...___________________ Esta es la nica garant a limitada expresa y el productor no autoriza ni otorga a alguien a realizar alguna otra obligaci n No existe ninguna otra garant a m s que la descrita en el...

Reviews: