4.  CHARGING THE INTERNAL BATTERY OF THE INSTANT POWER

IMPORTANT!

 CHARGE IMMEDIATELY 

AFTER PURCHASE, AFTER EACH 

USE AND EVERY 30 DAYS, TO KEEP 

THE INSTANT POWER’S INTERNAL 

BATTERY FULLY CHARGED AND 

PROLONG BATTERY LIFE.

CHECKING THE LEVEL OF THE 

INTERNAL BATTERY

Press the 

Battery Status

 button on 

the front of the unit. The LED lights will 

indicate the current charge level as 

follows:

RED –

 less than 20% of full charge; 

immediately charge the unit.

YELLOW/ORANGE –

 20-80% of full 

charge. 

GREEN –

 more than 80% of full charge.

CHARGING THE INTERNAL BATTERY

Charge the internal battery for the  

Instant Power using an extension cord 

(not included).

NOTE:

 Use of an improper extension  

cord could result in a risk of fire and 

electric shock. 

1. 

To charge, flip the AC connector on  

the back of the unit DOWN and plug in 

an 18 AWG or larger extension cord.

2. 

Plug the extension cord into a 120VAC 

electrical wall outlet.

3. 

While the jump starter is charging, the 

RED LED

 will be on. Complete charging 

may take up to 72 hours. When the 

RED LED

 turns off, the jump starter is 

ready to use.

4. 

When the internal battery is fully 

charged, the charger will automatically 

go into maintain mode and maintain 

the battery at full charge without 

damaging it. When in maintain mode, 

the 

GREEN LED will pulse

, as long 

as there is an AC cord connected to 

the charging port.

5. 

Charge the jump starter as soon as 

possible after use.

CHARGING THE INTERNAL BATTERY 

WHILE DRIVING

You may also charge the internal battery 

while driving, using a male-to-male  

charger cable (part number 94500109 –  

not included). 

IMPORTANT:

 DO NOT CHARGE 

INTERNAL BATTERY FOR MORE THAN 

30 MINUTES OR LEAVE THE BATTERY 

UNATTENDED. IT COULD EXPLODE, 

CAUSING PROPERTY DAMAGE OR 

PERSONAL INJURY. 

1. 

Make sure the car is running.

2. 

Insert one end of the accessory cable 

into the 12V DC power outlet. 

3. 

Insert the other end of the accessory 

cable into the vehicle’s accessory 

outlet (lighter socket). 

NOTE:

 The 

RED LED 

does not operate 

during this method of charging. Using this 

method to charge the battery overrides 

the maintain mode and the battery can be 

overcharged. 

4. 

Monitor the progress of the charge by 

pressing the 

Battery Status

 button 

on the front of the unit. When the 

battery is fully charged, disconnect 

the accessory cable from the Instant 

Power, then from the lighter socket of 

the vehicle. 

NOTE:

 Completely disconnect the charger 

cable when the engine is not running.

5.  USING THE INSTANT POWER

IMPORTANT:

 Using the Engine Start 

feature without a battery installed in the 

vehicle will damage the vehicle’s electrical 

system.

1. 

Turn the ignition OFF.

2. 

Lay the DC cables away from any  

fan blades, belts, pulleys and other 

moving parts.

3. 

For a negative-ground vehicle (as in 

most vehicles), connect the Instant 

Power’s POSITIVE (RED) clamp to 

the POSITIVE (POS, P, +) battery 

post. Next, connect the NEGATIVE 

(BLACK) clamp to the vehicle chassis 

or engine block, away from the battery. 

4. 

For a positive-ground vehicle, connect 

the Instant Power’s NEGATIVE 

(BLACK) clamp to the NEGATIVE 

(NEG, N, -) battery post. Next, 

connect the POSITIVE (RED) clamp 

to the vehicle chassis or engine block 

away from the battery.

5. 

Turn the switch to the ON position 

(does not apply to the XP400). 

NOTE:

 

The XP400 is equipped with an auto-

start feature. It will not supply current 

to the battery clamps until a battery is 

properly connected. The clamps will 

not spark if touched together. 

Summary of Contents for INSTANT POWER XP400

Page 1: ...ND READ BEFORE EACH USE This manual will explain how to use the Instant Power safely and effectively Please read and follow these instructions and precautions carefully POR FAVOR GUARDE ESTE MANUAL DE...

Page 2: ...ssional if service or repair is required Incorrect assembly may result in fire or electrical shock Do not use the Instant Power to jump a vehicle while charging the internal battery Do not recharge th...

Page 3: ...s bracelets necklaces and watches A battery can produce a short circuit current high enough to weld a ring to metal causing a severe burn Never smoke or allow a spark or flame in the vicinity of the b...

Page 4: ...INTERNAL BATTERY FOR MORE THAN 30 MINUTES OR LEAVE THE BATTERY UNATTENDED IT COULD EXPLODE CAUSING PROPERTY DAMAGE OR PERSONAL INJURY 1 Make sure the car is running 2 Insert one end of the accessory...

Page 5: ...more than 15A DC NOTE Extended operation of a 12V DC device may result in excessive battery drain Recharge the Instant Power immediately after unplugging the 12V DC device Estimated run times APPLIAN...

Page 6: ...position The Instant Power won t power my 12V device The 12V device is not turned on The Instant Power s battery is not charged The 12V device draws more than 15A or has a short circuit Turn on the 1...

Page 7: ...uct that are not manufactured by Schumacher Electric Corporation and approved for use with this product This Limited Warranty is void if the product is misused subjected to careless handling repaired...

Page 8: ...exponga el Instant Power a la lluvia o la nieve Nunca coloque el Instant Power directamente sobre la bater a que se est cargando Para evitar la formaci n de arcos el ctricos nunca permita que las pin...

Page 9: ...erruptor de APAGADO ENCENDIDO para el compresor de aire 11 Puerto interno del cargador de bater a 12 Sujetador para la manguera del compresor de aire 13 Manguera del compresor de aire 14 Adaptadores d...

Page 10: ...t n Estado de la bater a en la parte frontal de la unidad Cuando la bater a esta completamente cargada primero desconecte el cable auxiliar del Instant Power y luego de la toma del encendedor del veh...

Page 11: ...e 12V CC Tiempo estimado de funcionamiento TIPO DE DISPOSITIVO POTENCIA APROX XP400 XP750C Tel fono celular 4 vatios 13 hrs 34 hrs Luz fluorescente 4 vatios 15 hrs 34 hrs Radios ventiladores 9 vatios...

Page 12: ...nte de poder y coloque las pinzas en forma correcta Verifique la condici n de carga de la bater a girando el interruptor situado enfrente de la fuente de poder Consulte la secci n de Indicadores LED e...

Page 13: ...liente al 1 800 621 5485 NO ENV E LA UNIDAD hasta que usted reciba AUTORIZACI N DE DEVOLUCI N DE MERCANC A RMA de Servicios al Cliente de Schumacher Electric Corporation 9 ESPECIFICACIONES XP400 Tipo...

Page 14: ...an el Fabricante o si esta unidad es revendida a trav s de un vendedor minorista no autorizado El Fabricante no realiza ninguna otra garant a incluidas a t tulo enunciativo las garant as expresas impl...

Page 15: ...___________________ Esta es la nica garant a limitada expresa y el productor no autoriza ni otorga a alguien a realizar alguna otra obligaci n No existe ninguna otra garant a m s que la descrita en el...

Reviews: