54
4.
Rinse the air cooler thoroughly under running water and
allow to drain
5.
Replace the air cooler. The handle must be at the
bottom. Turn the lock levers back again to lock.
6.
Push the upper left edge of the maintenance flap until
the lock engages.
Cleaning the moisture sensor
After longer operation, small deposits (lime, fabric refiner)
can form on the front inner side of the drum on both
sides of the longish moisture sensors.
With moisture controlled programmes, this can result
in the desired level of dryness not being reached.
Wipe deposits away with a cloth soaked in vinegar.
Emptying the machine for frost protection or transport
If the machine is in a room susceptible to frost or is to be
transported, it must be completely emptied.
1.
Select any drying programme.
2.
Press the start button
. Any condensed water remai-
ning in the machine will then be pumped into the con-
tainer.
3.
Stop the programme after around 5 minutes using the
fast forward button
and empty the condensed water
container again.
Summary of Contents for 6697.0