background image

INSTALLATION ON A CEMENT CEILING 

 

 

Mounting the fan components: 

1- Choosing the fan height: 

Two downrods are included (short 15 cm and long 25 cm). The short downrod will already be pre-
assembled to the anti-wobble bracket. This gives a total height of 45 cm to the fan once mounted. 

If you want the fan to hang lower (55 cm), you must replace the short downrod with the long one. 

To do this you will need to remove the anti-wobble bracket, along with the mounting screws and pins from 
the short downrod and place them in the same position on the long downrod. 

2- Connecting the downrod to the fan body (motor) 

- Remove the lower pin from the downrod and slide up the canopy and decorative trim cover as per the 
diagram. 

- Feed the cables from the body (motor) through the inside of the downrod, until they come out the opposite 
end (ceiling bracket). Insert the downrod into the union ring and fix in place using the pin and the R clip and 
ensure it is secured in place using the locking screws.  Ensure they are screwed in proportionally on both 
sides. Cover with the decorative trim cover. 

 

 

Summary of Contents for ASPAS 316545

Page 1: ...ASPAS VENTILADOR DE TECHO 316545 GUÍA DE INSTALACIÓN Rev 03 21 ...

Page 2: ...ón RECOMENDACIONES DE SEGURIDAD Lea detenidamente este manual antes de comenzar la instalación y guarde estas instrucciones Para evitar una posible descarga eléctrica antes de instalar su ventilador desconecte la alimentación apagando el diferencial de línea de techo y el interruptor de pared asociado Todo el cableado debe estar de acuerdo con las normas eléctricas nacionales y locales Para reduci...

Page 3: ...es que pueden ocurrir Debe entenderse que el sentido común y la precaución son factores necesarios en la instalación y funcionamiento de este ventilador GUIA DE INSTALACIÓN Preparación de la instalación Para evitar lesiones personales y daños asegúrese de que la ubicación para colgar permita 2 3 metros libre desde suelo hasta las aspas y 76cm libres en la horizontal desde cualquier pared o element...

Page 4: ... retirar el anclaje antibalanceo los tornillos y pasadores de montaje que lleva el tubo corto y colocarlos en las mismas posiciones en el tubo largo 2 Unión del tubo al cuerpo motor Retirar el pasador inferior del tubo y pasar las tapas embellecedoras Canopí y tapa de unión según el esquema Pasar por el interior del tubo los cables provenientes del cuerpo motor hasta extraerlos por el lado opuesto...

Page 5: ...a en el esquema Volver a fijar los tornillos para inmovilizar el conjunto 4 Conexión a corriente Introducir el módulo de control en su ubicación dentro del Anclaje anti balanceo según esquema y conectar los cables del cuerpo siguiendo la guía de color y números indicados en el módulo Conectar los cables de corriente al módulo en los conectores asignados en el esquema ...

Page 6: ... Una vez conectado subir el canopí hasta el techo cubriendo el anclaje módulo y cableado Bloquear con los tornillos 5 Montaje de las palas Instalar las palas mediante los tornillos proporcionados ...

Page 7: ...laca LED a los cables que salen de la cara inferior del motor mediante la ficha de conexión rápida Después fijar la placa LED mediante sus imanes en el plafón metálico 7 Colocar el difusor de cristal Montar el difusor haciendo coincidir las ranuras del difusor con los suspensores del plafón y girar ...

Page 8: ...y tras el apagado prolongado se mantendrá en el siguiente encendido VENTILADOR 6 Velocidades Función VELOCIDAD VARIABLE Función INVERTER INVIERNO VERANO cambio de sentido de giro TEMPORIZADOR 1 hora 2 horas 4 horas 8 horas SCHULLER RECOMIENDA LA COLOCACIÓN DE PROTECTORES DE SOBRETENSIÓN PARA EVITAR LOS DAÑOS EN LOS COMPONENTES ELECTRÓNICOS DE LA LUMINARIA LED Disponibles en nuestro catálogo Para c...

Page 9: ...ASPAS CEILING FAN 316545 INSTALLATION GUIDE Rev 03 21 ...

Page 10: ...g installation SAFETY RECOMMENDATIONS Please read this manual carefully before commencing installation and keep the instructions safe To avoid possible electrical shock before installing your fan turn off the circuit breakers and wall switch to the fan supply line leads All wiring must be in accordance with national and local electrical standards To reduce the risk of personal injury do not bend o...

Page 11: ...rstood that common sense and caution are essential factors in the installation and operation of this fan INSTALLATION GUIDE Installation preparation To avoid personal injury and damage ensure that the hanging position allows for at least 2 3 meters between the floor and the blades and that there is at least 76cm of horizontal distance between the fan and any wall or other obstruction Make sure the...

Page 12: ...ong with the mounting screws and pins from the short downrod and place them in the same position on the long downrod 2 Connecting the downrod to the fan body motor Remove the lower pin from the downrod and slide up the canopy and decorative trim cover as per the diagram Feed the cables from the body motor through the inside of the downrod until they come out the opposite end ceiling bracket Insert...

Page 13: ...the diagram Secure the screws to fix the assembly firmly in place 4 Connecting to the power supply Insert the control module into its allocated slot in the anti wobble bracket as per the diagram and connect the cables from the fan body following the colour guide and numbers indicated on the module Connect the power cables to the module using the connectors assigned in the diagram ...

Page 14: ...Once connected raise the canopy until it is in place and covering the bracket module and wiring Fix in place using the screws provided 5 Assembling the blades Install the blades using the screws provided ...

Page 15: ...t the LED Board to the cables from the lower end of the motor using the quick splice connector Then fix the LED board in place onto the metal ring by means of the magnets 7 Fitting the glass shade Fit the glass shade by aligning the grooves on the shade with the supports on the metal ring and rotate ...

Page 16: ... tone the colour will be auto saved and after a prolonged shutdown it will remain the next time the light is turned on FAN 6 Speed Fan VARIABLE SPEED function INVERTER function WINTER SUMMER change of direction of rotation TIMER 1 hour 2 hours 4 hours 8 hours SCHULLER RECOMMENDS TO PLACE SURGE PROTECTORS TO AVOID DAMAGES TO THE ELECTRONIC COMPONENTS OF THE LED LUMINAIRE Available in our catalogue ...

Reviews: