background image

17

5. Cleaning and servicing.

5.1 Cleaning and disinfecting

5.1.1 Cleaning

Please clean all frame elements regularly with a spon-
ge or damp cloth; making sure that water droplets are 
removed. Please clean with a mild household deter-
gent for severer dirt. Thorough drying of the cleaned 
areas is important.
All fabrics that cannot be removed can be wiped with 
a moist cloth. For all removable fabrics please pay at-
tention to the sewn-in care labels (such as 

A

 + 

B

) on 

the respective element. Please also pay attention to 
our general cleaning and hygiene advice. This can be 
found at 

www.schuchmann.de/mediathek

.

5.1.2 Disinfection

Various products can be used for surface disinfection of metal and plastic 
parts. 
Liquid disinfectants are available as ready-to-use solutions that are spray-
ed on and evenly applied with a soft cloth. Alternatively, wipes pre-soaked 
with disinfectant can be used to wipe the products over the entire surface. 
In both cases, care must be taken to ensure complete wetting. Disinfection 
in fully automatic disinfection systems is also possible and recommended.
The exposure times may vary and can be found in the manufacturer's ins-
tructions for the products used.

5.2 Servicing

Please carry out a visual inspection on a daily basis and regularly check 
the product for cracks, breaks, missing parts and malfunctions. In case of a 
defect or malfunction, please contact the specialist dealer who supplied 
you with the product (see 

Point 8.5

).

5.3 Maintenance

For reasons of user safety and to retain product liability, the product must 
be subjected to maintenance by a specialist dealer at least once a year 
(see 

Point 8.5

). The maintenance work carried out must be documented in 

the maintenance plan (see 

Point 5.3.2

).

7190045

A

Obermaterial/

top cloth/dessus:

100% Polyester

B

Summary of Contents for madita hd

Page 1: ...Instructions for use madita hd The strong therapy chair madita hd ...

Page 2: ...s for use carefully prior to initial commissioning of the product and to observe them Please note that guidelines and representations in these Instructions for use may deviate from your product due to differing equipment We reserve the right to make technical modifications Important information Ensure that these Instructions for use remain with the product Your schuchmann Team ...

Page 3: ...tended purpose warning gui delines 07 2 5 Equipment for basic model 07 2 6 List of accessories 08 2 7 Product overview 08 3 Settings 09 3 1 Seat height 09 3 2 Seat angle 10 3 3 Seat depth 10 3 4 Back inclination 10 3 5 Back height 11 3 6 Armrests 11 3 7 Foot support 12 3 8 Castors 12 3 9 Weight 13 4 Accessories 14 4 1 Headrest 14 4 2 Thorax pelotte pads 14 4 3 Thigh guide 14 4 4 Adjustable pelvic ...

Page 4: ...Spare parts 20 5 5 Duration of use and re use 20 6 Technical data 21 7 Guarantee 21 8 Identification 22 8 1 EU Declaration of Conformity 22 8 2 Serial number date of manufacture 23 8 3 Product version 23 8 4 Issue of the document 23 8 5 Name and address of the manufacturer specialist dealer sup plying the product 23 Contents 04 ...

Page 5: ...preserve and protect the environment to prevent environmental pollution and to improve the recycling of raw materials please note the disposal instructions in points 1 3 1 and 1 3 2 1 3 1 Packaging The packaging of the product should be kept for any future transport that might be required Should you have to return the product for repairs or in case of a guarantee claim please if possible use the o...

Page 6: ... hd growing therapy chair is a medical product of risk class 1 and designed for use at home in nurseries and at school It can be used for all ages from early childhood to teenage years Individually adjustable seat dimensions and supporting pelotte pads allow a stable and upright sitting position Any other use or use over and above this purpose shall be considered not in accordance with the intende...

Page 7: ... an open fire or any other strong source of heat such as electric or gas heaters Only use accessories and spare parts made by Schuchmann otherwise you will endanger the user Only use the therapy chair if all components have been correctly mounted and adjusted Please ensure that none of the user s or accompanying person s extre mities are in the respective area when making adjustments of any kind t...

Page 8: ...harness 2 6 List of accessories Headrest Thorax pelotte pads torso guide Reinforced bracket for thorax pelotte pads Thigh guide Seat pad with anatomical leg guide Incontinence coating in the seat area Adjustable pelvic guide Knee abduction wedge Therapy table Weight max 3 weights possible 4 castors 100 mm all with lo cking device Wheel base extension Foot bench pad Table support pad Harness mounti...

Page 9: ... By pressing it lightly the seat unit slides upwards Lowering is achieved through pressure from abo ve onto the seat whilst at the same time operating the foot pedal The gas pressure spring serves merely to assist with adjustment of the height The foot pedal can be secured against unintentional operation with the spring pin C To do this turn the spring pin until it engages If neces sary assist eng...

Page 10: ...rds After each adjustment please retighten all screw connections 3 4 Back inclination The clamping lever D for the back angle adjustment can be found on the right side of the seat To adjust the back angle first loosen the hexagon socket screw E on the additional stabilisation of the seat angle F and remove the screw E Now release the clamping lever D and bring the back into the desired position Su...

Page 11: ...ts The armrests can be adjusted in height and width The height can be adjusted after loosening the star handle B The width can be adjusted after loosening the two grub screws C that can be found on both sides After each adjustment please retighten all screw connections Inconnectionwithatherapytable afteradjusting the width of the armrests also the brackets be lowthetableneedtobeadjusted seePoint4 ...

Page 12: ...the clamping lever D In order to continuously adjust the height please loosen the four grub screws E bring the foot support into the required position and retighten the grub screws E After each adjustment please retighten the clamping lever and the grub screws 3 8 Castors In general the therapy chair should be locked by braking the castors to avoid un intentional rolling away To do this press the ...

Page 13: ...In total up to three weights can be placed distributed at the front and back on the sub frame To remove the weight or to change the posi tion undo the grub screw B To change the width or the angle of the bra ckets D loosenthehexagonsocketscrews C A total of three weights can be attached to the sub frame After each adjustment please retighten all screw connections B C A D ...

Page 14: ... the rear with an Allen key C and bring the thorax pelotte pads into the desired position After each adjustment please retighten all screw connections 4 3 Thigh guide The thigh guide pads D can be individually adjusted in width and depth In order to adjust the width loosen the two wing screws E under the seat area and bring the thigh guide pad into the required position To adjust the depth please ...

Page 15: ...ustment please retighten all screw connections 4 5 Therapy table The therapy table can be adjusted in height and depth For the installation the tubes C are pushed into the receiver tubes D below the armrests Height adjustment takes place via adjust ment of the armrests see Point 3 6 To change the depth please loosen the two wing screws E and bring the table into the desired position Additionally a...

Page 16: ... should be able to hear it engage with an audible click 4 7 Wheel base extension The wheel base extension 10 cm can only be mounted at the rear of the sub frame and cannot be adjusted It is only used for stability especially when the seat angle is tilted backwards 4 8 Foot support pad Thefootsupportpad B isfixedbelowthefoot support using hook and loop Use the avai lable slots on the foot support s...

Page 17: ...d evenly applied with a soft cloth Alternatively wipes pre soaked with disinfectant can be used to wipe the products over the entire surface In both cases care must be taken to ensure complete wetting Disinfection in fully automatic disinfection systems is also possible and recommended The exposure times may vary and can be found in the manufacturer s ins tructions for the products used 5 2 Servic...

Page 18: ...lity of other adjustment elements back headrest pelotte pads armrests footrests table and guides in the leg area Functionality of the gas pressure springs if necessary readjustment of the bowden cables Functionality of the safety elements anti tilt Correct mounting of the seat unit Functionality of brakes Functionality of the rollers concentricity smooth running Check the harness for damage clampi...

Page 19: ...tenance specifications of the manufacturer see Point 5 3 1 were car ried out Date Company Name signature Any defects or damage found must be repaired by the specialist dealer or the manufacturer before reuse 5 Cleaning and servicing ...

Page 20: ...riod if it is in a safe condition The expected duration of use does not refer to wear parts such as for example wheels gas pressure springs The maintenance and evaluation of the condition and if applicable the potential for re use must be decided by the specialist dealer The product is suited for re use Prior to forwarding please follow the clea ning and disinfection instructions stated in Point 5...

Page 21: ...we shall after carriage paid return to us view the indicated damage and if applicable either repair or deliver a new product at our discretion madita hd A Seat depth 30 42cm B Seat width 28 38cm C Back height with short back 42 52cm C Backrest height with long back 53 63cm D Seat height 46 58cm E Lower leg length 30 48cm F Total width 53cm G Length of base frame 77cm Seat angle 5 20 Back angle 5 2...

Page 22: ... Standards entspricht is are in conformity with the requirements of the below listed directives and standards Verordnung EU 2017 745 über Medizinprodukte vom 05 April 2017 Regulation EU 2017 745 on medical devices of 5 April 2017 DIN EN 12182 2012 Technische Hilfen für behinderte Menschen Technical aids for disabled persons DIN EN ISO 14971 2013 Medizinprodukte Anwendung des Risikomanagements auf ...

Page 23: ...address of the manufacturer specialist dealer supplying the product This product was manufactured by This product has been delivered by the following specialist dealer Schuchmann GmbH Co KG Rudolf Runge Str 3 49143 Bissendorf Germany Phone 49 0 5402 40 71 00 Fax 49 0 5402 40 71 109 info schuchmann de www schuchmann de 8 Identification A Product name Item number Serial number schuchmann de info sch...

Page 24: ...schuchmann de GA 30HD EN_1 1 ...