VME64x System Subrack 2 U

Service

20836-245

www.schroff.biz

12

R1.0, July 14, 2009

4  Service

4.1  Technical support and Return for Service Assistance

We generally recommend to return the complete subrack system. For all product 
returns and support issues, please contact your Schroff sales distributor or 

www.schroff.biz

.

We recommend that you save the packing material. Shipping without the original 
packing material might void the warranty.

4.2  Declaration of Conformity

VME64x systems are not an end product. In order to make them operational, 
further assemblies are necessary.

In accordance with the definition in the EMC directives it is not classified as 
equipment, therefore a CE certification is not required. The systems do, 
however, fulfil all requirements in a full assembled state to the standard of EMC 
guideline 89/336/EWG and the low voltage guideline 73/23/EWG.
Generally the systems are equipped with power supplies, which have a CE 
certification (EN 60950, EN 61000-6-3, EN 61000-6-2).

The selection of the filter elements is carried out with consideration of the 
hysteresis curve to EN 55022, class B. Interference resistance is guaranteed in 
accordance with EN 61000-6-2. Shielding measurements in the frequency area 
of 30 MHz to 1000 MHz to VG directive 95 373, Part 15, are carried out.

The systems were developed and manufactured in accordance with EN 60950. 
Before delivery each systems undergoes a voltage, protective earth and 
functionality test.

Summary of Contents for VME64x

Page 1: ...VME64x System Subrack 2 U User s Manual Product No 20836 245 July 14 2009 Doc No 63972245_R1 0...

Page 2: ...Management System to EN ISO 9001 2000 The company cannot accept any liability for errors or misprints The company reserves the right to amendments of technical specifications due to further developme...

Page 3: ...Overview 4 2 2 VME64x Backplane 5 2 3 Power Backplane 5 2 4 Power Supply 6 2 4 1 Grounding Earthing 6 2 4 2 Plug In AC Power Supply Order separately 7 2 4 3 Wiring Diagram 8 2 5 Cooling 9 3 Assembly...

Page 4: ...VME64x System Subrack 2 U 20836 245 www schroff biz II R1 0 July 14 2009...

Page 5: ...s no valid approval for these units In order to enable stand alone functionality additional elements are required An operational system is achieved only by way of appropriate VME64x boards The complet...

Page 6: ...ns to avoid accidents before starting to work with parts that carry dangerous voltages Caution This is the user caution symbol It indicates a condition where damage of the equipment or injury of the s...

Page 7: ...anual VME64x J1 J2 Monolithic Backplanes Order no 73972 128 Short Form User Manual Power Backplane 23098 115 Order no 73972 072 Operating Instructions maxpowerPRO 250 W Power Supply 13100 141 Order no...

Page 8: ...supplies Power input module with IEC 320 C14 connector mains line switch mains line filter and fuses 2 1 Subrack System Overview Figure 1 Subrack System Overview The 2 U 19 steel chassis is black pow...

Page 9: ...nector for the Fan Tray Further information can be found in the user manual of the backplane Order No 73972 103 in the catalogue or on the internet at www schroff biz 2 3 Power Backplane A Power Backp...

Page 10: ...ieved through the protective earth conductor of the power cable Hazardous voltage Parts of the power supply may be exposed with hazardous voltage Always remove mains line connector before carry out an...

Page 11: ...upply e 10006814 Input voltage nominal 100 240 VAC Mains Frequency 50 60 Hz Output max 250 W Output voltages 3 3 5 0 12 0 12 0 V V V V 40 40 5 5 2 A A A A Ripple 1 Dynamic response 1 or 60 mV Recovery...

Page 12: ...VME64x System Subrack 2 U Product Definition 20836 245 www schroff biz 8 R1 0 July 14 2009 2 4 3 Wiring Diagram Figure 4 Wiring Diagram 10009834...

Page 13: ...Fan Monitor Module FMM are located on a hot pluggable Fan Tray The fan speed is monitored by the Fan Monitor Module FMM When the fan speed drops 20 below nominal fan speed the FMM will signal a fault...

Page 14: ...ck whenever possible If installation in an enclosed rack is unavoidable ensure that the rack has adequate ventilation Maintain ambient airflow to ensure normal operation If the airflow is blocked or r...

Page 15: ...asks have to be carried out Ensure that the system has not been damaged during transport storage or assembly Carry out a new test for the protective earth set value 0 1 Ohm Switch on the system and ch...

Page 16: ...ives it is not classified as equipment therefore a CE certification is not required The systems do however fulfil all requirements in a full assembled state to the standard of EMC guideline 89 336 EWG...

Page 17: ...de rails inc ESD clips ESD clip assembled at the right 1 Rear card cage for max 4 boards 6 U 80 mm deep IEEE guide rails inc ESD clips 2 Slots for 2 plug in power supplies 1 Complete AC DC cabling 1 P...

Page 18: ...put up to 500 W Cooling 2 x 12 VDC fans 69 m h 40 cfm each free blow Ambient Temperature Operation 0 C to 50 C Storage 40 C to 85 C Humidity Admissible humidity 30 to 80 non condensing EMC fulfils req...

Page 19: ...VME64x System Subrack 2 U Dimensions 20836 245 www schroff biz 15 R1 0 July 14 2009 6 Dimensions Figure 7 Dimensions...