CORPORATE OFFICE
5620 Business Park • San Antonio, Texas 78218 • T 210 662 8200 • F 210 667 2600 • TF 877 404 2488 • www.schroederamerica.com
“Schroeder America” is a trademark of Schroeder Industries, Inc. Patents Pending, US & Foreign.
4. Ensure Return to Proper Operation
A. Verify all electrical and mechanical connections are properly made and secure.
B. Turn CO
2
back on and check for proper pressure setting at CO
2
regulator (100 PSI). Verify tank
connections are secure and leak free.
C. Turn water supply back on to tank and again check for any leaks.
D. Reconnect the unit to electrical power and look for the green LED on the control module to light
up. This indicates proper functioning/install of the conversion kit.
1. If green LED does not illuminate:
a. Verify all wiring is correct.
b. If problem persists, contact Schroeder America.
GREEN LED
E.
Carbonator should start a refill cycle after a 10 second start delay if demand is present. If tank
is at or above the full level of the new probe assembly, initiate demand by draining some water
from the tank by opening a down-stream dispensing valve.
F.
Verify carbonator functions normally once refill level is met and carbonation levels are
satisfactory.
NOTE:
It may take several refill cycles to generate and stabilize the carbonation level at the point of dispense