background image

J1034-UV-A/B/E DETECTOR Manual 

 

USER INFORMATION 

Thank  you  for  using  the  UV  broadband  detector.  Make  sure  to  read  this 
instruction  manual  thoroughly  and  to  understand  the  contents  before  starting  to 
operate the instrument. Keep this manual at safe and handy place for whenever it 
is needed. 
 
For any questions, please contact us at the CMS office given below. 
 
CMS reserve the right to make changes to specifications without prior notice. 
 
 

Warranty 

 
For  warranty  terms  and  conditions,  contact  CMS  or  your  distributor  for  further 
details. 
 
CMS  guarantees  that  the  product  delivered  to  customer  has  been  verified, 
checked  and  tested  to  ensure  that  the  product  meets  the  appropriate 
specifications. The product warranty is valid only if the product has been installed 
and used according to the directives provided in this instruction manual. 
CMS  shall  in  no  event  be  liable  for  incidental  or  consequential  damages  arising 
from the faulty and incorrect use of the product. 
In  case  of  any  manufacturing  defect,  the  product  will  be  repaired  or  replaced 
under warranty. However, the warranty does not apply if: 

 

Any modification or repair was done by any person or organization other 
than CMS service personnel.

 

 

The damage or defect is caused by not respecting the instructions of use 
as given on the product brochure or the instruction manual.

 

 

Contact Information 

 
CMS Ing. Dr. Schreder GmbH 
 
Lofererstraße 32 
6322 Kirchbichl 
Austria 
 
Tel.:  +43 (0)5332 / 77056-00 
Fax:  +43 (0)5332 / 77056-14 
 
E-Mail:  [email protected] 
Web: 

www.schreder-cms.com

 

Summary of Contents for J1034-UV-A

Page 1: ...34 UV A B E DETECTOR USER S MANUAL C M S In g D r Sc h re de r G m b H Lofererstraße 32 A 6322 Kirchbichl Tel 43 0 5332 77056 00 Fax 43 0 5332 77056 14 E Mail info schreder cms com Web www schreder cms com ...

Page 2: ...ake one copy of the software disk for backup purposes The software may not be copied or distributed in any other way No part of this manual may be reproduced or transmitted in any form or by any means electronic optical or mechanical including photocopying and recording or by any information storage and retrieval system without permission in writing from CMS Ing Dr Schreder GmbH ...

Page 3: ...1 WARRANTY 1 CONTACT INFORMATION 1 SAFETY INFORMATION 2 WARNING CAUTION 2 VOLTAGE WARNING 2 GENERAL DESCRIPTION 3 TECHNICAL DATA 3 PIN CONNECTION OF ALL UV DETECTORS 3 RELATIVE SPECTRAL RESPONSE 4 MOUNTING AND ALIGNMENT 5 COMPONENTS PARTS REFERENCE 6 LIST OF ADDITIONAL PARTS 6 REFERENCES 6 ...

Page 4: ...s the appropriate specifications The product warranty is valid only if the product has been installed and used according to the directives provided in this instruction manual CMS shall in no event be liable for incidental or consequential damages arising from the faulty and incorrect use of the product In case of any manufacturing defect the product will be repaired or replaced under warranty Howe...

Page 5: ...ation base should have enough load capacity for the instrument to be mounted Fix the equipment securely Otherwise the instrument may drop due to gale or earthquake which may lead to unexpected accidents Make sure the instrument and the cables are installed in a location where they will not get soaked Voltage Warning Power Supply Make sure to check the power supply voltage and type AC DC before con...

Page 6: ...6 1999 CIE S 007 E 1998 265 315 nm 310 400 nm 280 400 nm See individual detectors Type Single band Dual band Cosine error f2 1 5 Cosine Response 2 5 between 0 and 70 solar zenith angle Measure range 0 0 6 W m 0 5 W m 0 100 W m 0 100 W m 0 100 0 0 5 W m 0 100 0 0 5 W m Signal output 0 5 V on request 0 2 5 V Temperature range 40 C 60 C Temp coefficient 0 1 K Power Supply 9 24 V 0 75mA Time switch on...

Page 7: ...ure 1 Relative Spectral Response of the single band detectors Erythemal weighting function ERY defined ISO 17166 1999 CIE S 007 E 1998 260 280 300 320 340 360 380 400 10 4 10 3 10 2 10 1 10 0 WAVELENGTH nm RELATIVE SPECTRAL RESPONSE ERY UV E AE UV A AE Figure 2 Relative Spectral Response of the dual band detector Erythemal weighting function ERY defined ISO 17166 1999 CIE S 007 E 1998 ...

Page 8: ... to the UV detector The additional available Detectorbase 105303 is a general purpose base plate which fits directly to the J1033 Shadowring 103304 It allows a robust and quick alignment to individual grounds Use the tilting screws to align the detector and control the correct settings with the help of the spirit level After that use the montage screws to fix the detector to the ground Figure 3 UV...

Page 9: ...AW Report No 141 Report of the LAP COST WMO Intercomparison of Erythemal Radiometers Thessaloniki Greece 1999 WMO TD No 1051 2 WMO GAW Report No 146 Quality Assurance in Monitoring Solar Ultraviolet Radiation the State of the Art WMO TD No 1180 3 WMO GAW Report No 164 Instruments to measure Ultraviolet Radiation Part 2 Broadband Instruments Measuring Erythemally Weighted Solar Radiation WMO TD No ...

Reviews: