Concrete Floor
Lag Screw
Bushing
Compressor Foot
Rubber Pad
Lag Shield
Stationary Air Compressor Mounting Kit
For Electric Models only. Order 824678.
Stationary Air Compressor Mounting Instructions
1. Select a location for mounting unit on a firm and
level floor.
2. Position unit and mark feet location in center hole of
each foot.
3. Prepare to drill holes by removing unit.
4. Drill each of the marked holes 3" in depth using a 3/4"
concrete drill bit. Blow out holes and insert lag shield
making sure they are flush with the floor.
5. Position unit over drilled holes.
6. Place one rubber isolation pad under each foot.
7. Assemble 1 1/2" metal/rubber washer and lag bolt into
each lag shield. Do not over tighten.
Flex Air Line Installation
1. Install 3/4" NPT nipple into tank outlet hole
2. Install 3/4" NPT Ball Valve.
3. Install 3/4" x 36" Flexible Hose.
Note: Teflon Tape should be used on all thread connections.
MOUNTING FOR STATIONARY AIR COMPRESSOR ONLY.
Correct
Wrong
Disconnect power and release air pressure before
installing and/or performing maintenance.
UNPACKING INSTRUCTIONS
The two stage compressor was inspected at the factory and
packaged to protect against shipping damage. When you
unpack your unit, inspect for damaged or missing parts. If
there are any damaged or missing parts, the transportation
company’s agent should make a notation to the effect on
the Bill of Lading. Claims, should be settled directly with the
transportation company.
All Vertical Compressors are top heavy and can easily
tip over. Use appropriate lifting device for moving unit
to desired location. When using air compressors and
compressed air accessories, basic safety rules and
precautions should always be followed. Read the
compressor operating instruction before attempting to
assemble, install, operate, or maintain the product. Failure
to comply with the safety instructions could result in
personal injury and/or property damage.
The compressor must be placed in a clean and well
ventilated room.
Compressor should be located at least
18-30 inches away from a wall or other obstruction that
will impede air flow through the fan-bladed flywheel. Do
not place compressor where heat is excessive. Provide
adequate fresh air and exhaust ventilation from area in
which the compressor is located.Place compressor on
a firm, level floor. Remove wood shipping skid before
installation.
Failure to remove from wooden skid will void
all warranties.
Permanent installations should be bolted to
the floor. Bolting holes are provided in the base feet. Shim
compressor level before bolting down to floor. Avoid putting
stress on your new compressor by using our Mounting Kit
(824678).
Tank Drain
D. Flex Hose
C. Ball Valve
A. Nipple
B. Outlet Hole
B
C
D
36" Flex Hose
Warning: May bend & curve; do not kink.
A