background image

Owner’s Manual

150 Watt 
Tungsten Halogen 
Light Source

CSA Listed to UL-1571 

LIGHT SOURCE MODELS  115 VAC/60Hz 

230 VAC/50Hz/60Hz 

SOLID STATE RHEOSTAT 

A20500 

EKE Lamp 

A20500.1 

EJA Lamp 

A20500.2 

DDL Lamp 

A20510 

EKE Lamp

A20510.1

EJA Lamp 

A20510.2 

DDL Lamp 

SOLID STATE RHEOSTAT 
AND IRIS DIAPHRAGM 

A20520 

EKE Lamp 

A20520.1 

EJA Lamp 

A20520.2 

DDL Lamp 

A20530 

EKE Lamp 

A20530.1 

EJA Lamp 

A20530.2 

DDL Lamp 

122 Charlton Street, Southbridge, MA 01550-1960

Summary of Contents for ACE A20500

Page 1: ...z 60Hz SOLID STATE RHEOSTAT A20500 EKE Lamp A20500 1 EJA Lamp A20500 2 DDL Lamp A20510 EKE Lamp A20510 1 EJA Lamp A20510 2 DDL Lamp SOLID STATE RHEOSTAT AND IRIS DIAPHRAGM A20520 EKE Lamp A20520 1 EJA Lamp A20520 2 DDL Lamp A20530 EKE Lamp A20530 1 EJA Lamp A20530 2 DDL Lamp 122 Charlton Street Southbridge MA 01550 1960 ...

Page 2: ...Phone 508 765 9744 Fax 508 765 1299 Email lightingimaging us schott com www us schott com lightingimaging ...

Page 3: ...igh output fan provides maximum airflow resulting in extremely cool operation We suggest you read this manual carefully to become familiar with all the light source features and how they work MAINTENANCE Although your light source is designed to be maintenance free it does contain sensitive electronic parts TREAT IT WITH CARE TO ASSURE BEST PERFORMANCE The original packaging should be used for pro...

Page 4: ...cause burns Operators are advised to allow the unit to cool before opening or relamping Modulamp assembly ...

Page 5: ...eptacle and tighten the fiber optic positioning thumbscrew Adjust the intensity of the lamp using the control knob To turn the unit off turn the intensity control knob to the OFF position OPERATIONS 1 Mettre l interrupteur sur position off 2 Connecter le cordon d alimentation à la source et le brancher au secteur 3 Vérifier que la vis sur la face avant du module lampe soit fermement visée 4 Insére...

Page 6: ...iefern 4 Feststellschraube des Lampeneinschubes fest anziehen 5 Kompatibles Faserbündel in den Faserbündeladapter der Lichtquelle einführen 6 Feststellschraube des Faserbündeladapters anziehen 7 Netzschalter in ON Stellung bringen 8 Intensität der Lampe mit Kontrollpotentiometer auf gewünschten Wert einstellen 9 Zum Abschalten der Lichtquelle den Netzschalter in OFF Stellung bringen FUNZIONAMENTO ...

Page 7: ...S MAY AFFECT THE LAMP OUTPUT Push the ceramic socket on the two lamp pins until flush with the reflector TO REPLACE THE MODULAMP ASSEMBLY Slide the connector into the mating receptacle until the release tab clicks into place Place the Modulamp assembly into the recess with the two bottom ears riding over the bottom edge of the recess first Slide the Modulamp assembly into place and depress the cap...

Page 8: ...settings may be changed by moving the lamp holder into the correct position Consult the factory for correct lamp locations ...

Page 9: ...l enchufe cerámico 10 Deslizar la Modulámpara en las orejas del origen de luz por encima del borde del fondo al principio 11 Apretar el tornillo LAMPENWECHSEL 1 Nettzschalter in OFF Stellung bringen 2 Faserbündeladapter herausziehen 3 Lampe abkühlen lassen 4 Feststellschraube des Lampenienschubes so lange lösen bis die Einschubkassette herausspringt 5 An der Oberseite des Lampeneinschubes ziehen u...

Page 10: ...a del cavo 6 Abbassare il dispositivo di sgancio del portalampada per rimuovere la lampadina 7 Delicatamente staccare il portalampada in ceramica 8 Inserire la nuova lampadina nel portalampada NON toccare il bulbo o l interno del riflettore 9 Spingere la lampadina nel portalampada in ceramica fino a livello di base ...

Page 11: ...rriscaldate SAFETY INSTRUCTIONS 1 READ UNDERSTAND AND FOLLOW ALL INSTRUCTIONS in this manual 2 KEEP all safety and operating instructions for future reference 3 HEED ALL WARNINGS on the unit and in this manual 4 DO NOT USE this unit near water or in any area with excessive moisture 5 MOUNT on surface platform or wall ONLY as recommended by the manufacturer 6 DO NOT BLOCK ventilation openings in th...

Page 12: ...is no light check the following in sequence 1 Turn the Intensity Control knob to 100 2 Change the bulb 3 Examine lamp socket for damage Check continuity of wiring If contacts are carburized or the ceramic base is cracked or the wiring is frayed replace socket 4 Make sure that the two pin modular connector is properly engaged in the locking position see lamp replacement section Check contacts for p...

Page 13: ... 50Hz Models A20510 A20530 Output 21VAC Power Consumption 190 Watts nominal Lamp Types Tungsten Halogen 150 Watt 21 Volt EJA EKE 150 Watt 20 Volt DDL CSA to UL 1571 Improvements may result in specification or feature changes without notice PARTS LIST EJA Lamp A08110 Rheostat Control Knob H09033 100 EKE Lamp A08120 Iris Control Knob H09050 045 DDL Lamp A08130 Fuse 10 pkg 115 V units A08126 Lamp Soc...

Page 14: ......

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ......

Page 19: ...fic legal rights and there may be additional rights which vary from State to State Some States for example do no allow exclusion of consequential damage SERVICE POLICY Any service required for any reason must be performed by the manufacturer or an authorized service representative All service out side the warranty will be performed upon the purchaser s request according to normal service charges i...