background image

8 of 13

Service Manual UK

English

Any obstruction such as supports or side panels, must be removed to allow 15 mm minimum depth 
below the base of the gas hob. Any overhead surface of combustible material must not be closer than 
650 mm. See Fig. 2 and Fig. 3.

It is recommended that the hob be installed at a distance of at least 55 mm from the rear wall or other 
vertical surfaces to ensure that the air circulated properly over the cooking area and to avoid 
overheating the surrounding surfaces. See Fig. 3.

If a cooker hood is to be installed, refer to the manufacturers instructions regarding fixing heights.

FITTING THE HOB

Unpack the hob from the carton. Remove the bag containing the sealing tape, fixing brackets and 
screws. Make sure that the seal adheres properly to the bottom part of the frame of the hob.
The seal must fit properly around the entire hob frame and especially along the corners in order to 
create a seal between the work top and the hob itself so as to prevent spills or splashes from leaking 
into the cabinet below. The hob must be fixed into the work top using the fixing clamps as shown in Fig. 
4 below.

It is essential to install the hob on a totally flat surface. Any damage caused by incorrect fitting may 
alter the characteristics or impair performance.

Insert the hob into the hole, pressing firmly around the frame to make it adhere to the counter top.

Connect the hob to the gas supply and check for gas tightness.

Fig. 2

Fig. 3

Fig. 4

Summary of Contents for PMG41DCDRSF

Page 1: ...s UK 2010 Reg Office Peterborough PE2 9JB Registered in London 106725 Service Information 38 cm GAS HOBS Models Comm Covered Code Single Ring PMG41DCDRSF 57506 2 Ring PMG42SF 57507 5413143 Issue 1 Oc...

Page 2: ...th your appliance 5 Genuine Scholt s UK spares should always be used when repairing Scholt s UK products For UK customers the fitting of non genuine spares could affect your rights under the product l...

Page 3: ...PMG42SF 57507 Stainless Steel TECHNICAL DATA GENERAL LPG Conversion Kits are available C00090735 model PMG41 C00089138 model PMG42 COUNTRY OF ORIGIN Italy OVERALL DIMENSIONS Height 54 mm PMG41 47 mm P...

Page 4: ...l power kW H s By pass 1 100 mm Injector 1 100 mm Flow g h Injector 1 100 mm Flow l h Nomin Reduc G30 G31 G20 D Triple Ring 130 3 25 1 3 57 91 236 232 124 309 A Auxiliary 55 1 00 0 4 30 50 73 71 71 95...

Page 5: ...ndition where it could be connected to the electricity supply To help the environment Local Authority instructions should be followed for the disposal of the product Disposal of Old Electrical Applian...

Page 6: ...dance with the current edition of the above regulations It is in your interest and that of safety to ensure compliance with the law In the UK Gas Safe CORGI in Northern Ireland registered installers w...

Page 7: ...lt s Built In Ovens The hob should be checked to ensure that the voltage corresponds with the voltage supply this is stated on the rating plate which is situated on the base panel These hobs are desig...

Page 8: ...the hob from the carton Remove the bag containing the sealing tape fixing brackets and screws Make sure that the seal adheres properly to the bottom part of the frame of the hob The seal must fit pro...

Page 9: ...t correspond with the coloured marking identifying the terminals in the plug if this is the case proceed as follows The wire which is coloured BLUE must be connected to the terminal which is marked wi...

Page 10: ...most appropriate burner to cook with CONTROL KNOBS for the gas burners adjust the power and size of the flame IGNITION for the gas burner enables a specific burner to be lit automatically SAFETY DEVIC...

Page 11: ...he hob top d Remove the 2 screws that secure the 2 control taps to the hob top 1 screw per tap e Lift the hob top clear f Reassemble in reverse order 2 TO ACCESS THE CONTROLS a Disconnect the hob from...

Page 12: ...ps noting that the Blue leads and microswitches are still connected e Remove the 2 screws securing the brackets on the gas rail to the control taps Remove the control tap assemblies from the gas rail...

Page 13: ...f 13 Service Manual UK English WIRING DIAGRAM 66 22 L N 22 Tf Tp 66 66 230V 50Hz 15 Transformer Spark Generator Terminal Block Microswitch 22 Brown 66 Light Blue 15 Yellow Green 5413143wd pdf PMG41 PM...