DESCRIPTION OF THE APPLIANCE

OVERALL VIEW - PMG42 shown

GAS BURNERS differ in size and power. Use the diameter of the cookware to choose the most 
appropriate burner to cook with.

CONTROL KNOBS for the gas burners adjust the power and size of the flame.

IGNITION for the gas burner enables a specific burner to be lit automatically.

SAFETY DEVICE stops the flow of gas if the flame is accidentally extinguished.

GAS BURNERS

Support Grid for
COOKWARE

Control Knobs for
GAS BURNERS

S A F E T Y

DEVICES

Ignition for
GAS BURNERS

Summary of Contents for PMG41DCDRSF

Page 1: ...s UK 2010 Reg Office Peterborough PE2 9JB Registered in London 106725 Service Information 38 cm GAS HOBS Models Comm Covered Code Single Ring PMG41DCDRSF 57506 2 Ring PMG42SF 57507 5413143 Issue 1 Oc...

Page 2: ...th your appliance 5 Genuine Scholt s UK spares should always be used when repairing Scholt s UK products For UK customers the fitting of non genuine spares could affect your rights under the product l...

Page 3: ...PMG42SF 57507 Stainless Steel TECHNICAL DATA GENERAL LPG Conversion Kits are available C00090735 model PMG41 C00089138 model PMG42 COUNTRY OF ORIGIN Italy OVERALL DIMENSIONS Height 54 mm PMG41 47 mm P...

Page 4: ...l power kW H s By pass 1 100 mm Injector 1 100 mm Flow g h Injector 1 100 mm Flow l h Nomin Reduc G30 G31 G20 D Triple Ring 130 3 25 1 3 57 91 236 232 124 309 A Auxiliary 55 1 00 0 4 30 50 73 71 71 95...

Page 5: ...ndition where it could be connected to the electricity supply To help the environment Local Authority instructions should be followed for the disposal of the product Disposal of Old Electrical Applian...

Page 6: ...dance with the current edition of the above regulations It is in your interest and that of safety to ensure compliance with the law In the UK Gas Safe CORGI in Northern Ireland registered installers w...

Page 7: ...lt s Built In Ovens The hob should be checked to ensure that the voltage corresponds with the voltage supply this is stated on the rating plate which is situated on the base panel These hobs are desig...

Page 8: ...the hob from the carton Remove the bag containing the sealing tape fixing brackets and screws Make sure that the seal adheres properly to the bottom part of the frame of the hob The seal must fit pro...

Page 9: ...t correspond with the coloured marking identifying the terminals in the plug if this is the case proceed as follows The wire which is coloured BLUE must be connected to the terminal which is marked wi...

Page 10: ...most appropriate burner to cook with CONTROL KNOBS for the gas burners adjust the power and size of the flame IGNITION for the gas burner enables a specific burner to be lit automatically SAFETY DEVIC...

Page 11: ...he hob top d Remove the 2 screws that secure the 2 control taps to the hob top 1 screw per tap e Lift the hob top clear f Reassemble in reverse order 2 TO ACCESS THE CONTROLS a Disconnect the hob from...

Page 12: ...ps noting that the Blue leads and microswitches are still connected e Remove the 2 screws securing the brackets on the gas rail to the control taps Remove the control tap assemblies from the gas rail...

Page 13: ...f 13 Service Manual UK English WIRING DIAGRAM 66 22 L N 22 Tf Tp 66 66 230V 50Hz 15 Transformer Spark Generator Terminal Block Microswitch 22 Brown 66 Light Blue 15 Yellow Green 5413143wd pdf PMG41 PM...