5.7 MV3 Valve (abrasive metering valve)
The MV3 Valve (#14) is used to control (meter) abrasive flow by use of an adjustable orifice.
The size of this orifice is controlled by turning the knob at the top of the MV3 Valve. Turning
the knob clockwise reduces the orifice size which decreases abrasive flow. Turning the knob
counterclockwise increases the orifice size which will increase the abrasive flow to the blast
nozzle (#11). Adjustments to the abrasive flow should be made by turning the knob a little at a
time. Test the adjustment by starting the blast for a short period to determine if further
adjustment is needed. The MV3 Valve has an orifice indicator on the body to use as reference
as to the amount the orifice is open.
Note:
For proper operation, the MV2® abrasive flow must
be in the direction of the base arrow (see Section 9.5(a)). However, this does not apply to MV3.
The MV3 Valve has a cleanout port used to purge trash that blocks abrasive flow. This is done
by removing the clean out cap and pressing down the deadman lever (#12). The blast air flow
purges trash through the clean out (see Section 11.3.2). The cleanout is then reinstalled for
operation.
Airborne particles and loud noise hazards from purged air can cause serious injury and loss of
hearing. Wear approved eye and ear protection. Stay clear of purge air path. DO NOT place hands
or other body parts in the purge air path. Make sure no personnel are in the purge air path.
5.8 Deadman Valve/Switch (blast control)
The Deadman valve/switch is part of the system that controls the blast operation. The deadman
allows the operator to remotely start and stop the blast operation. The deadman is mounted at
the end of the blast hose assembly (#10) near the blast nozzle (#11) to give the operator easy
control of the blast operation.
The Deadman is either a pneumatic valve or an electric switch depending on the type of
abrasive blaster control system. When the deadman lever is pressed down it sends either a
pneumatic or electric signal to the ComboValve®. The ComboValve opens and starts the blast
operation. See Sections 9.1, 9.2, 9.3, 9.8, and 9.9.
5.8.1.
Pneumatic Deadman System:
When the pneumatic deadman (#12) lever is pressed
down, air supply from the orange hose of the twinline hose (#15) flows into the black
hose. Air flows through the black hose to the signal port of the ComboValve (#4) to
open it and send air into the abrasive blaster and blast air hose. When the deadman lever
is released, the air signal is cut off and the ComboValve is closed to shut off the supply
air and depressurize the blaster through the blowdown hose assembly (#9). See Figure
5.3 and the drawings in Sections 9.1 and 9.2.
Figure 5.3 – MV3/Combo Pneumatic Deadman Blast Control System
Summary of Contents for MV3
Page 18: ...18 Copyright 2021 Axxiom Manufacturing Inc 2 7 Abrasive Blaster Strapping Packing Detail ...
Page 36: ...36 Copyright 2021 Axxiom Manufacturing Inc THIS PAGE IS INTENTIONALLY BLANK ...
Page 58: ...58 Copyright 2021 Axxiom Manufacturing Inc 9 4 MICROVALVE ...
Page 59: ...59 Copyright 2021 Axxiom Manufacturing Inc 9 5 a MV2 Valve ...
Page 60: ...60 Copyright 2021 Axxiom Manufacturing Inc 9 5 b MV3 Valve ...
Page 61: ...61 Copyright 2021 Axxiom Manufacturing Inc 9 6 COMBOVALVE ...
Page 62: ...62 Copyright 2021 Axxiom Manufacturing Inc 9 7 Control Valves pneumatic and electric ...
Page 63: ...63 Copyright 2021 Axxiom Manufacturing Inc 9 8 a G2 Pneumatic Deadman ...
Page 64: ...64 Copyright 2021 Axxiom Manufacturing Inc 9 8 b Deadman Valves Pneumatic ...
Page 66: ...66 Copyright 2021 Axxiom Manufacturing Inc 9 10 Volumetric Blowdown Suppression System VBS II ...
Page 77: ...77 Copyright 2021 Axxiom Manufacturing Inc NOTES ...
Page 78: ...78 Copyright 2021 Axxiom Manufacturing Inc NOTES ...