Instructions for Use
– SCHMIDT
®
Flow Sensor SS 20.500
Page 20
Through-bolt joint
V4A
532160
G
1
/2
39
SW17
SW27
14
Ø 9,2
+0,1
- Immersion sensor
- Pipe (typ.), wall
- Screwing into a welding
stud
- Material:
Stainless steel 1.4571
PTFE
Atmospheric pressure use!
Through-bolt joint
Brass
16
a.) 524891
b.) 524919
- Immersion sensor
- Tube (typ.), wall
- Screwing into a welding
stud
- Material:
FKM
a.) Brass
c.) Stainless steel
Pressure-tight up to 10 bar!
Wall mounting
flange
520181
- Immersion sensor
- (plane) wall
- Screw on with 2 screws
- Material:
Stainless steel 1.4401
PTFE, NBR
Atmospheric pressure use
(pressure-tight
≤ 500 mbar)
Table 3
Notes:
The supplied connecting cables generally consist of media-resistant
materials (thread ring made of stainless steel, sheathing and enclo-
sure made of PUR).
The connecting cable with fixed length is not free of halogen.
The connecting cable with adjustable length (lead insulation made of
modified PP) as well as the coupler socket is free of halogen.
All mounting fixtures fasten the sensor by means of frictional clamp-
ing. This enables stepless positioning of the sensor in the holder con-
cerning its immersion depth and axial adjustment. Accordingly, posi-
tioning and alignment of the sensor tip in the flow field must be carried
out with great care. Make sure to tighten fastening screw properly,
especially for applications with overpressure.
16