EFA bung dropper Translation of the original operating instructions
EN
V 05.2021
17 of 27
1
2
3
4
2)
Press the operating lever (1), the intestine is held by the vacuum while the
rotating blade (2) makes the cut.
3)
Release the operating lever (1), switch off the rotating blade
(2) and the vacuum.
If the vacuum is not turned off, faeces will emerge from the
intestine.
If work is interrupted for a longer period of time,
disconnect the machine from the compressed air
network.
6.2.3
Operational safety
Bung dropper
Hold the machine securely by both handles (4 + 5). Never work one-handedly without the additional
handle (4).
Be especially careful when switched on.
Never operate the operating lever when the device is not in use.
After switching off, the bung dropper comes to a standstill within 3 s.
For safe handling (guiding), the bung dropper must be suspended from a spring balancer,
see section
5.1.1 Spring balancer
.
Vacuum system
Never connect the vacuum system to the compressed air network.
Never place the open end of the vacuum hose on any part of the body.
Never exceed the max. capacity of the tank.
Only switch on the vacuum motor while working with the cutting device.
For complete information about the vacuum system, read the operating instructions supplied with it.
Fig. 6.2
– Working with the
bung dropper
5