background image

ZQ 700

Operating instructions
Pull-wire emergency-stop switches

EN

1

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 
need for the mounting, set-up and commissioning to ensure the safe 
operation and disassembly of the safety switchgear. The operating inst-
ructions must be available in a legible condition and a complete version 
in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 
be carried out by trained specialist personnel, authorised by the plant 
operator only.

Please make sure that you have read and understood these operating 
instructions and that you know all applicable legislations regarding 
occupational safety and accident prevention prior to installation and 
putting the component into operation.

The machine builder must carefully select the harmonised standards to 
be complied with as well as other technical specifications for the selec-
tion, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 
execute safety-related functions as part of an entire plant or machine. It 
is the responsibility of the manufacturer of a machine or plant to ensure 
the correct functionality of the entire machinery or plant.

The safety switchgear must be exclusively used in accordance with the 
versions listed below or for the applications authorised by the manufac-
turer. Detailed information regarding the range of applications can be 
found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating instruc-
tions manual, the country-specific installation standards as well as all 
prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 
catalogues or in the online catalogue on the Internet:  
www.schmersal.net.

The information contained in this operating instructions manual is provi-
ded without liability and is subject to technical modifications.

There are no residual risks, provided that the safety instructions as well 
as the instructions regarding mounting, commissioning, operation and 
maintenance are observed.

1.6  Warning about misuse

In case of improper use or manipulation of the safety switch-
gear, personal hazards or damages to machinery or plant 
components cannot be excluded.

Content

About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 

Target group: authorised qualiied personnel

. . . . . . . . . . . . . . . . . . 1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3  Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 

Safety classiication

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.3  Mounting set-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . . 3
4.2  Contact variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Set-up and maintenance

5.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Disassembly and disposal

6.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Appendix

7.1  EC Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

 573753 / 02.2014

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 6

Translation of the original operating instructions

Summary of Contents for ZQ 700-11

Page 1: ...sively used in accordance with the versions listed below or for the applications authorised by the manufac turer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country specific installation standards as well as all prevai...

Page 2: ...of the emergency stop signal the reason why the switch has been actuated must be determined The switch can only be reset if the switch is correctly pre tensioned position indication in central position refer to image 1 The entire concept of the control system in which the safety component is integrated must be validated to the relevant standards 2 4 Technical data Standards IEC EN 60947 5 1 IEC EN...

Page 3: ...s in the central position refer to image 1 As the thimbles are subject to deformation in case of wire pull the wire should be pulled several times after fitting After that the wire must be re tensioned see image 4 Image 4 deformation of the wire thimbles In order to ensure an optimal operation safety and to save time during fitting we recommend using the wire rope and the combined fixing and tensi...

Page 4: ...Maintenance A regular visual inspection and functional test including the following steps is recommended 1 Check the functionality of the switch by actuating the wire 2 Check the cable entries and the wire connections 3 Remove particles of dust and soiling 4 Check the wire tension through the wire position indication and check the wire and the wire guides for damages and proper fitting Do not open...

Page 5: ...tly valid declaration of conformity can be downloaded from the internet at www schmersal net EC Declaration of conformity Translation of the original Declaration of Conformity ACE Schmersal Eletroeletrônica Industrial Ltda Rodovia Boituva Porto Feliz Km 12 Jardim Esplanada CEP 18550 000 Boituva SP Brasil Internet www schmersal com br We hereby certify that the hereafter described safety components...

Page 6: ...0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com Production site ACE Schmersal Eletroeletrônica Industrial Ltda Rodovia Boituva Porto Feliz Km 12 Jardim Esplanada CEP 18550 000 Boituva SP Brasil Telefone 55 0 15 32 63 9800 Telefax 55 0 15 32 63 9890 E Mail vendas schmersal com br Internet http www schmersal com br ...