schmersal TESF series Operating Instructions Manual Download Page 1

TESF

Operating instructions

Hinge safety switch

EN

1

1. About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure the safe 

operation and disassembly of the safety switchgear. The operating 

instructions must be available in a legible condition and a complete 

version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards to 

be complied with as well as other technical specifications for the selec-

tion, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional informa-

tion.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine. It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the correct functionality of the entire machine or plant.

The safety switchgear must be exclusively used in accordance with the 

versions listed below or for the applications authorised by the manufac-

turer. Detailed information regarding the range of applications can be 

found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating instruc-

tions manual, the country-specific installation standards as well as all 

prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

www.schmersal.net.

The information contained in this operating instructions manual is pro-

vided without liability and is subject to technical modifications.

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed.

1.6  Warning about misuse

In case of improper use or manipulation of the safety switch-

gear, personal hazards or damages to machinery or plant 

components cannot be excluded when safety switchgear is 

used. The relevant requirements of the standard ISO 14119 

must be observed.

Content

1  About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2 

Target group: authorised qualified personnel

. . . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.4  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.5 

Safety classification

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

3  Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

4  Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . .3

4.2  Contact variants. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

4.3  Switch travel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

4.4  Door gap calculation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

5  Set-up and maintenance

5.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

5.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

6  Disassembly and disposal

6.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

6.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

7  EU Declaration of conformity

x.0

00

 / 

Ja

nu

ar

 2

01

/ v

.A

.  

 - 

  1

01

18

30

77

-E

N

 / 

H

 / 

20

17

-0

1-

02

 / 

A

E

-N

r. 

69

38

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 6

Original

Summary of Contents for TESF series

Page 1: ...e applications authorised by the manufac turer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country specific installation standards as well as all prevailing safety regulations and accident prevention rules Further tech...

Page 2: ... be validated to the relevant standards 2 4 Technical data Standards IEC 60947 5 1 BG GS ET 15 Enclosure Zinc diecast enclosure cover self extinguishing thermoplastic Hinge bolt Stainless steel 1 4305 Contact material Silver gold plated Protection class IP65 Contact type Change over contact with double break Zb Switching system A IEC 60947 5 1 slow action NC contact with positive break Connection ...

Page 3: ...41 5 25 5 41 5 22 11 4 TESF TESF S 6 1 100 25 5 25 5 41 5 41 5 75 5 115 4 11 21 5 90 M16x1 5 51 40 6 1 55 51 51 25 5 41 5 25 5 41 5 22 11 4 4 Electrical connection 4 1 General information for electrical connection The electrical connection may only be carried out by authorised personnel in a de energised condition For the cable entry only suitable cable glands and for the connector suitable plugs ...

Page 4: ...nt is set the opening of the set ting option imperatively must be sealed with a blanking plug This measure prevents tampering at the set switching point within the meaning of ISO 14119 paragraph 7 and therefore avoids any loss of the safety function of the device The blanking plug is injected to the special adjustment tool with a predetermined breaking point We recommend an additional painting or ...

Page 5: ...26 7 251 7 1 500 78 5 104 6 130 7 156 7 182 7 208 7 234 5 260 3 β Door opening angle C Door width in mm D Door gap in mm for overlapping B 0 mm B Door thickness Calculation example The actual door gap D1 is calculated using door gap D calculated by means of the table above minus the overlapping B of door and frame D1 D B Example A door made of 40 mm aluminium profile with a length of 950 mm should...

Page 6: ...Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com Place and date of issue Wuppertal January 2 2017 Authorised signature Philip Schmersal Managing Director EU Declaration of conformity Original K A Schmersal GmbH Co KG Möddinghofe 30 42279 Wuppertal Germany Interne...

Reviews: