11
SRB-E-204ST / SRB-E-204PE
Operating instructions
Safety-monitoring module
EN
8.4 Setting report
This report regarding the setting of the device must be completed
accordingly by the customer and enclosed in the technical
documentation of the machine.
The setting report must be available whenever a safety check is
performed.
Company:
The safety-monitoring module is used in the following machine:
Machine n°
Machine type
Module n°
Configured application (mode):
Set on (date)
Signature of the responsible person
8.5 Maintenance
A regular visual inspection and functional test, including the following
steps, is recommended:
1. Check the correct fixing of the safety-monitoring module
2. Check the cable for damages
3. Check electrical function
If a manual functional check is necessary to detect a
possible accumulation of faults, then this must take place
during the intervals noted as follows:
• at least every month for PL e with category 3 or
category 4 (according to ISO 13849-1) or SIL 3 with HFT
(hardware fault tolerance) = 1 (according to IEC 62061);
• at least every 12 months for PL d with category 3
(according to ISO 13849-1) or SIL 2 with HFT (hardware
fault tolerance) = 1 (according to IEC 62061).
Damaged or defective components must be replaced.
9. Disassembly and disposal
9.1 Disassembly
The safety-monitoring module must be disassembled in a de-energised
condition only.
9.2 Disposal
The safety-monitoring module must be disposed of in an appropriate
manner in accordance with the national prescriptions and legislations.
10.
Appendix
10.1 Wiring/circuit information
Use of safety outputs Q1, Q2
Safety outputs Q1, Q2 are to be used for safety-orientated signal
processing.
SRB-E-204PE:
To realise additional safety functions, outputs Q1, Q2 can be evaluated
with safety relay modules SRB or safety controllers.