Operating instructions

Safety relay module

SRB 301MC

SRB 301MC-ST

EN

1.6  Warning about misuse

In case of inadequate or improper use or manipulations of 

the safety-monitoring module, personal hazards or damage 

to machinery or plant components cannot be excluded. 

The relevant requirements of the standards ISO 14119 and 

ISO 13850 must be observed.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual. The manufacturer shall accept no liability for damages 

resulting from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary 

repairs, conversions and modifications to the device are strictly 

forbidden, the manufacturer shall accept no liability for damages 

resulting from such invasive work, arbitrary repairs, conversions and/or 

modifications to the device.

The safety-monitoring module must only be used when the enclosure is 

closed, i.e. with the front cover fitted.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

SRB 301MC

No. Option

Description

Screw connection

-ST

Plug-in screw connection

Only if the information described in this operating instructions 

manual are realised correctly, the safety function and therefo-

re the compliance with the Machinery Directive is maintained.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 

these specifications apply accordingly, provided that they correspond to 

the standard version.

2.3  Purpose

The safety-monitoring modules for integration in safety circuits are 

designed for fitting in control cabinets.  They are used for the safe 

evaluation of the signals of positive break position switches or magnetic 

safety sensors for safety functions on sliding, hinged and removable 

safety guards as well as emergency stop control devices and AOPDs.

The safety function is defined as the opening of the enabling circuits 

13-14, 23-24 and 33-34 when the inputs S11-S12 and/or S21-S22 are 

opened.

The safety-relevant current paths with the outputs contacts 13-14, 23-

24 and 33-34 meet the following requirements under observation of a 

PFH value assessment (also refer to chapter 2.5 "Safety classification"):

• Control category 4 - PL e to ISO 13849-1-1  

• SIL 3 to IEC 61508-2  

• SILCL 3 to IEC 62061

To determine the Performance Level (PL) to ISO 13849-1-1 of the 

entire safety function (e.g. sensor, logic, actuator), an assessment of all 

relevant components is required.

The entire concept of the control system, in which the safety 

component is integrated, must be validated to the relevant 

standards.

2.4  Technical data

General data:

 

Standards:

 

IEC 60204-1, IEC 60947-5-1,ISO 13849-1, IEC 61508

Climate resistance:

 

EN 60068-2-78

Mounting:

 

snaps onto standard rail to EN 60715

Terminal designations:

 

IEC 60947-1

Material of the housings:

  Plastic, glass-fibre reinforced thermoplastic, 

ventilated

Material of the contacts:

 

AgSnO, self-cleaning, positive drive

Weight:

 

230 g

Start conditions:

 

Automatic or start button 

Feedback circuit (Y/N):

 yes

Pull-in delay for automatic start:  

typ. 100 ms, max. 160 ms

Pull-in delay with reset button: 

typ. 15 ms, max. 20 ms

Drop-out delay in case of emergency stop: 

typ. 20 ms, max. 25 ms

Drop-out delay on "supply failure":

 

typ. 80 ms

Bridging in case of voltage drops: 

 

typ. 80 ms

Mechanical data:

 

Connection type:

 

refer to 2.1 Ordering code

Cable section:

 

min. 0.25 mm² / max. 2.5 mm²

Connecting cable:

 

rigid or flexible

Tightening torque for the terminals: 

 

0.6 Nm

With removable terminals (Y/N):

 

refer to 2.1 Ordering code

Mechanical life:

 

10 million operations

Electrical life: 

 

Derating curve available on request

Resistance to shock:

 

10 g / 11 ms

Resistance to vibration in accordance with EN 60068-2-6:

 10 to 150 Hz, 

Amplitude 0.35 mm

Ambient temperature:

 

−25 °C … +60 °C

Storage and transport temperature:

 

−40 °C … +85 °C

Protection class:

 

Enclosure: IP40  

Terminals: IP20  

Clearance: IP54

Air clearances and creepage distances  

to IEC 60664-1:

 

4 kV/2 (basic insulation)

EMC rating: 

 

to EMC Directive

Electrical data:

 

Contact resistance in new state:

 

max. 100 mΩ

Power consumption:

 

max. 2.0 W / 4.9 VA

Rated operating voltage U

e

:

 

24 VDC −15% / +20%, 

 

residual ripple max. 10%

 

24 VAC −15% / +10%

Frequency range:

 

50 / 60 Hz

Fuse rating for the operating voltage:

 

Internal electronic trip, tripping 

current > 500 mA, reset after approx. 1 sec.

Monitored inputs:

 

Cross-wire detection (Y/N): 

 Yes

Wire breakage detection (Y/N): 

 Yes

Earth leakage detection (Y/N): 

 Yes

Number of NO contacts:

 0

Number of NC contacts:

 2

Cable length:

 

1,500 m with 1.5 mm² 

2,500 m with 2.5 mm²

Conduction resistance:

 

max. 40 Ω

Outputs:

 

Number of safety contacts:

 3

Number of auxiliary contacts:

 1

Number of signalling outputs:

 0

Max. switching capacity of the safety contacts:

 

 

- 13-14, 23-24, 33-34

 

 

max. 250 V, 8 A ohmsch (ohmic  

 

(inductive in case of suitable protective wiring), 

 

min. 10 V / 10 mA,  

 

residual current at ambient temperature up to:  

 

45 °C: 24 A, 55 °C: 18 A, 60 °C: 12 A

Switching capacity of the auxiliary contacts:

 

41-42: 24 VDC / 2 A

Summary of Contents for SRB 301MC

Page 1: ...odule must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found...

Page 2: ...061 To determine the Performance Level PL to ISO 13849 1 1 of the entire safety function e g sensor logic actuator an assessment of all relevant components is required The entire concept of the contro...

Page 3: ...e enclosure slightly tilted forwards in the standard rail and push up until it latches in position To avoid EMC disturbances the physical ambient and operational conditions at the place where the prod...

Page 4: ...S12 14 24 34 S21 42 X2 A2 S22 41 X1 A1 S12 18 28 38 S22 45 X1 A1 nQS QS Fig 1 Fig 2 Fig 3 6 Set up and maintenance 6 1 Functional testing The safety function of the safety monitoring module must be te...

Page 5: ...l emergency stop circuit with command devices to ISO 13850 and IEC 60947 5 5 Fig 7 Wire breakage and earth leakage in the control circuits are detected Category 1 PL c to ISO 13849 1 possible Dual cha...

Page 6: ...toring module is only admitted when the requirements of the standard IEC 60947 5 3 are observed As the technical data are regarded the following minimum requirements must be met switching capacity min...

Page 7: ...ype test T V Rheinland Industrie Service GmbH Alboinstr 56 12103 Berlin ID n 0035 EC prototype test certificate 01 205 5035 01 16 Person authorised for the compilation of the technical documentation O...

Page 8: ...K A Schmersal GmbH Co KG M ddinghofe 30 42279 Wuppertal Germany Phone 49 202 6474 0 Telefax 49 202 6474 100 E Mail info schmersal com Internet www schmersal com...

Reviews: