schmersal SRB 220XV2 V.2 Operating Instructions Manual Download Page 8

8

EN

SRB220XV2V

.2-D-EN

Operating instructions

Safety-monitoring module

SRB 220XV2 V.2

9.  EU Declaration of conformity

The currently valid declaration of conformity can be  

downloaded from the internet at www.schmersal.net.

Place and date of issue:

Wuppertal, November 22, 2017

Authorised signature

Philip Schmersal

Managing Director

EU Declaration of conformity

Original

K.A. Schmersal GmbH & Co. KG

Möddinghofe 30

42279 Wuppertal

Germany

Internet: www.schmersal.com

We hereby certify that the hereafter described components both in their basic design and construction conform 

to the applicable European Directives. 

Name of the component:

SRB220XV2 V.2

Description of the component:

Safety-monitoring module for emergency stop circuits and  

guard door monitoring

Relevant Directives:

Machinery Directive

EMC-Directive

RoHS-Directive

2006/42/EC

2014/30/EU

2011/65/EU

Applied standards:

EN 60947-5-1:2004 + AC:2005 + A1:2009,

EN ISO 13849-1:2015,

EN ISO 13849-2:2012

Notified body, which approved 

the full quality assurance sys-

tem, referred to in Appendix X, 

2006/42/EC:

TÜV Rheinland Industrie Service GmbH

Alboinstr. 56, 12103 Berlin

ID n°: 0035

Person authorised for the compilation  

of the technical documentation:

Oliver Wacker

Möddinghofe 30

42279 Wuppertal

K. A. Schmersal GmbH & Co. KG

Möddinghofe 30, D - 42279 Wuppertal

Postfach 24 02 63, D - 42232 Wuppertal 

Phone:  +49 - (0)2 02 - 64 74 - 0 

Telefax:  +49 - (0)2 02 - 64 74 - 1 00

E-Mail: [email protected]

Internet: http://www.schmersal.com

Summary of Contents for SRB 220XV2 V.2

Page 1: ...versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description To avoid EMC dist...

Page 2: ...th the output contacts 13 14 and 23 24 meet the following requirements under observation of a B10D value assessment also refer to Requirements to DIN EN ISO 13849 1 control category 4 PL e to DIN EN I...

Page 3: ...results in the below mentioned switching cycle times tcycle for the relay contacts Diverging applications upon request Contact load nop y tcycle 20 525 600 1 0 min 40 210 240 2 5 min 60 75 087 7 0 min...

Page 4: ...saved in the SRB 220XV2 the voltage supply must be interrupted for approx 3 seconds ON ON SW1 SW2 1 1 2 2 3 3 4 4 Fig 3 New adjustable drop out delays and cross wire short monitoring for version V 2...

Page 5: ...iptions and legislations 8 Appendix 8 1 Wiring examples Dual channel control shown for a guard door monitor with two contacts A and B where at least one is a positive break contact with external reset...

Page 6: ...s between the control circuits are detected Control category 4 to EN 954 1 Category 4 PL e to DIN EN ISO 13849 1 possible Single channel guard door monitoring circuit with interlocking devices to EN 1...

Page 7: ...s S feedback circuit If the feedback circuit is not required establish a bridge S33 S34 47 13 48 14 KB KA S L1 N KA KC S33 S34 47 13 48 14 KB KC KD KA KB L1 N KA KD KC S Fig 18 Fig 19 Differential con...

Page 8: ...omponent SRB220XV2 V 2 Description of the component Safety monitoring module for emergency stop circuits and guard door monitoring Relevant Directives Machinery Directive EMC Directive RoHS Directive...

Reviews: