1.4  Appropriate use

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the correct functionality of the entire machine or plant

The safety switchgear must be exclusively used in accordance with 

the versions listed below or for the applications authorised by the 

manufacturer Detailed information regarding the range of applications 

can be found in the chapter "Product description"

1.5  General safety instructions

The user must observe the safety instructions in this operating 

instructions manual, the country specific installation standards as well 

as all prevailing safety regulations and accident prevention rules

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

productsschmersalcom

The information contained in this operating instructions manual is 

provided without liability and is subject to technical modifications

The entire concept of the control system, in which the safety 

component is integrated, must be validated to EN ISO 13849-2

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed

Additional measures could be required to ensure that the system does 

not present a dangerous breakdown, when other forms of light beams are 

available in a special application (eg use of wireless control devices on 

cranes, radiation of welding sparks or effects of stroboscopic lights)

1.6  Warning about misuse

In case of improper use or manipulation of the safety switch-

gear, personal hazards or damages to machinery or plant 

components cannot be excluded The relevant requirements 

of the standards ISO 13855 and EN ISO 13857 must be 

observed

Only if the information described in this operating instructions 

manual are realised correctly, the safety function and therefore 

the compliance with the Machinery Directive is maintained

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual The manufacturer shall accept no liability for damages 

resulting from the use of unauthorised spare parts or accessories 

For safety reasons, invasive work on the device as well as arbitrary 

repairs, conversions and modifications to the device are strictly 

forbidden; the manufacturer shall accept no liability for damages 

resulting from such invasive work, arbitrary repairs, conversions and/or 

modifications to the device

2.  Product description

2.1  Purpose

The SLC/SLG440COM is a non-contact, self-testing safety guard 

(AOPD), which is used for the protection of hazardous points, 

hazardous areas and machine accesses If one or more light beams are 

interrupted, the hazardous movement must be stopped

The user must evaluate and design the safety chain in 

accordance with the relevant standards and the required 

safety level

2.2  Bluetooth interface

The 440COM series is equipped with a Bluetooth interface (BLE) as 

standard The interface is integrated into the receiver This technology, 

in conjunction with the Schmersal app 'SLC Assist', gives you access to 

all relevant information about the AOPD

The app can be downloaded from the relevant app store for iOS and 

Android devices 

2.3  Ordering code

This operating instructions manual applies to the following types:

SLC440COM-ER-

-

No. Option

Description

xxxx

Protection field heights in mm available lengths:  

0330, 0410, 0490, 0570, 0650, 0730, 0810, 

0890, 0970, 1050, 1130, 1210, 1290, 1370, 

1450, 1530*, 1610*, 1690*, 1770*, 1850*, 1930*

14

Resolution 14 mm with a range of 03 m …  7 m

30

Resolution 30 mm with a range of 03 m …  10 m

35

Resolution 35 mm with a range of 03 m …  7 m

*  Resolution 14 mm:  

protection field height 1530 … 1930 mm with a range of 03 m … 6 m

*  Resolution 35 mm:  

protection field height 1850 … 1930 mm with a range of 03 m … 6 m

SLG440COM-ER-

No. Option

Description

Distance between outermost beams:

0500-02

500 mm, 2 beams

0800-03

800 mm, 3 beams

0900-04

900 mm, 4 beams

Range 03 m  12 m

2.4  Special versions

For special versions, which are not listed in the order code, these 

specifications apply accordingly, provided that they correspond to the 

standard version

2.5  Included in delivery

• Sensors E, R (emitter and receiver with integrated status lamp)

• Mounting kit MS-1100

• Operating instructions DE/EN

• Spacer MSD5, with protection field height of 1050 mm or higher

Summary of Contents for SLC440COM Series

Page 1: ...ion 1 1 2 Target group authorised qualified personnel 1 1 3 Explanation of the symbols used 1 1 4 Appropriate use 2 1 5 General safety instructions 2 1 6 Warning about misuse 2 1 7 Exclusion of liabil...

Page 2: ...ccept no liability for damages and malfunctions resulting from defective mounting or failure to comply with this operating instructions manual The manufacturer shall accept no liability for damages re...

Page 3: ...oad inductance 4 0 2H Function protective mode automatic restart interlock setting mode Connection Emitter connector M12 4 pole Receiver connector M12 5 pole Ambient temperature 10 C 50 C Storage temp...

Page 4: ...ction zone interrupted OSSD signal low Green ON state protection zone uninterrupted OSSD signal high 2 9 2 Restart Interlock operation In the operating mode restart interlock the safety switching outp...

Page 5: ...ta or cyan For the parameter setting follow the instructions as described in the section Parameter setting with adapter cable KA 0896 4 Mounting 4 1 General conditions The following guidelines are pro...

Page 6: ...llow operating mode restart interlock 3 Adjust the emitter and receiver so that they are in the middle of the angular range for a green or yellow indication Fix the position with the two screws for ea...

Page 7: ...is exposed to serious injuries To calculate the minimum distances of the safety guards with regards to the hazardous point the EN ISO 13855 and EN ISO 13857 must be observed If an overlap of the prote...

Page 8: ...e 1 Locate the height of the upper edge of the hazardous area a left table column 2 Locate the height of the protection area b upper table row 3 CRO is to be taken from the crossing point of both axes...

Page 9: ...h neighbouring safety light barriers grids of the same type AOPD is excluded If two or more applications are arranged so that mutual interference is possible this should be eliminated with a partition...

Page 10: ...C440COM ER 0970 xx Ls 1024 13 1011 mm 4 8 Dimensions 4 8 1 Dimensions emitter and receiver SLC440COM All measurements in mm 75 A B C 22 2 24 7 7 33 27 8 Type A Protected height 1 B Mounting dimension...

Page 11: ...on description Length 103010816 A K5P M12 S G 5M BK 2 X A 4 69 Female connector M12 5 pole 5 m 103010818 A K5P M12 S G 10M BK 2 X A 4 69 Female connector M12 5 pole 10 m 103010820 A K5P M12 S G 15M BK...

Page 12: ...ed BK 24 VDC BN 0 VDC BU Release restart GY 24 VDC BN OSSD 2 BK OSSD 1 WH 0 VDC BU Not connected WH Protective mode Automatic active Delivery state Pushbutton S1 not connected Restart Interlock manual...

Page 13: ...of the emitter is correctly connected to the emitter and the connecting cable of the receiver is correctly connected to the receiver 4 The double insulation between the light curtain output and an ex...

Page 14: ...Green static Status of OSSD safety switch outputs is ON protection field is clear OSSD OFF Red static Status of OSSD safety switch outputs is OFF the protection field is interrupted Restart interlock...

Page 15: ...003 This device complies with Industry Canada s license exempt RSS standard s Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accep...

Page 16: ...205 13144609 Person authorised for the compilation of the technical documentation Oliver Wacker M ddinghofe 30 42279 Wuppertal Place and date of issue M hldorf May 11 2020 Authorised signature Klaus S...

Reviews: