14
Operating instructions
Safety light curtain / safety light grid
SLC440 Series
SLG440 Series
EN
4.6 Dimensions
4.6.1 Dimensions emitter and receiver SLC440
All measurements in mm
57
8,
07
A
B
C
2,
22
42
7,7
33
27,8
Type
A
Protected
height
± 1
B
Mounting
dimension
± 1
C
Total
length
± 1
SLC440-ER-0170-XX
170
264
283
SLC440-ER-0250-XX
250
344
363
SLC440-ER-0330-XX
330
424
443
SLC440-ER-0410-XX
410
504
523
SLC440-ER-0490-XX
490
584
603
SLC440-ER-0570-XX
570
664
683
SLC440-ER-0650-XX
650
744
763
SLC440-ER-0730-XX
730
824
843
SLC440-ER-0810-XX
810
904
923
SLC440-ER-0890-XX
890
984
1003
SLC440-ER-0970-XX
970
1064
1083
SLC440-ER-1050-XX
1050
1144
1163
SLC440-ER-1130-XX
1130
1224
1243
SLC440-ER-1210-XX
1210
1304
1323
SLC440-ER-1290-XX
1290
1384
1403
SLC440-ER-1370-XX
1370
1464
1483
SLC440-ER-1450-XX
1450
1544
1563
SLC440-ER-1530-XX
1530
1624
1643
SLC440-ER-1610-XX
1610
1704
1723
SLC440-ER-1690-XX
1690
1784
1803
SLC440-ER-1770-XX
1770
1864
1883
SLC440-ER-1850-XX
1850
1944
1963
SLC440-ER-1930-XX
1930
2024
2043
4.6.2 Dimensions emitter and receiver SLG440
75
70,8
A
B
C
22,2
24
7,7
33
27,8
L2
L1
41,5
82,5
Type
A
Beam
distance
B
Mounting
dimension
C
Total
length
L1
L2
SLG440-ER-0500-02
500
624
643
3585 3575
SLG440-ER-0800-03
400
924
943
2585 2175
SLG440-ER-0900-04
300
1024
1043
2585 2175
The overall length Ls (dimension end cap with regard to the cable
connection up to the connector M12) of the sensors is calculated in the
following way:
Ls = size B - 13 mm
Example SLC440-ER-0970
Ls = 1064 - 13 mm
Ls = 1051 mm
L1 = Mounting distance (mm) between floor and slotted hole centre
(short end cap)
L2 = Mounting distance (mm) between floor and slotted hole centre
(diagnostic window)
The integrated status indication
does not
change the mounting
dimension B or the overall length C The overall length of the Ls
receiver changes by 10 mm
24,5
12,5
¤ 15