3.3  Dimensions

All measurements in mm.

Safety sensor

106

91

74

78

9

25

4,

5

19

6,

5

M1

2

2

22

0,3

0,3

Coding Level: High

V2

Actuator

91

78

25

22

0,3

0,3

0,3

V2

Alternative suitable actuators with different design: refer 

to www.schmersal.net. 

3.4  Switch distance

Switching distances to IEC 60947-5-3:

Typical switching distance s

typ

:  

12 mm 

Assured switching distance s

ao

10 mm

Assured switch-off distance s

ar

20 mm

There are new switch distances as per the table below 

owing to the necessity of technical modifications (V2).

Please check the design of your guard system following 

installation to ensure adherence to the secured switch 

distances (≤ s

ao

 and ≥ s

ar

) in accordance with the specified 

values and adjust the guard system accordingly.

The positions of the designations V2 should be gleaned 

from the dimensional drawings under 3.3.

Switching distances 

in mm  

to IEC 60947-5-3

Actuator  

RST

Actuator  

RST V2

Sensor  
RSS

s

typ

12

12

s

ao

10

8

s

ar

16

16

Sensor  
RSS V2

s

typ

12

12

s

ao

10

10

s

ar

20

20

With the combination of "old sensor - new actuator (V2)" 

there may be limitations in availability owing to the reduced 

s

ao

 (8 mm). This change has no affect on the performance 

level.

The side allows for a maximum height misalignment (X) of sensor 

and actuator of ± 8 mm (e.g. mounting tolerance or due to guard door 

sagging). The axial misalignment (y) is max. ± 18 mm.

Y

X

Latching versions X ± 5 mm, Y ± 3 mm.  

The latching force will be reduced by misalignment.

Actuating curves

The actuating curves represent the typical switching distance of 

the safety sensor during the approach of the actuator subject to the 

actuating direction

Transverse misalignment

-5

-20

5

10 15

-15

20

-10

0

Y [mm]

S [mm]

0

5

10

12

Height misalignment

-5

-20

-24

5

10 15

-15

20 24

-10

0

X [mm]

S [mm]

0

5

10

12

Preferred actuation directions: from front or from side

3.5  Adjustment

The continuous signal of the yellow LED signals the actuator detection; the 

flashing of the yellow LED signals that the safety sensor is actuated in the 

hysteresis area. 

Recommended Adjustment

Align the safety sensor and actuator at a distance of 0.5 x s

ao

.  

The correct functionality of both safety channels must be checked by 

means of the connected safety-monitoring module.

Summary of Contents for RSS36-ST-AS

Page 1: ...rding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual labe...

Page 2: ...ition for as long as the safety guard is open The safety switchgears are classified according to ISO 14119 as type 4 switching devices Designs with individual coding are classified as highly coded and...

Page 3: ...de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement 2 6 Safety classification S...

Page 4: ...2 sao 10 10 sar 20 20 With the combination of old sensor new actuator V2 there may be limitations in availability owing to the reduced sao 8 mm This change has no affect on the performance level The s...

Page 5: ...following teach in procedure 1 Switch the safety sensor s voltage supply off and back on 2 Introduce the actuator in the detection range The teach in procedure is signalled at the safety sensor yellow...

Page 6: ...green flashing Off 1 static 0 Internal device error periphery error red green flashing Flashes 1 1 static 0 AS i error slave address 0 or communication error red depending on the condition 0 static 0...

Page 7: ...lar visual inspection and functional test including the following steps is recommended 1 Check the safety function 2 Check the fixing and integrity of the safety switchgear the actuator and the cable...

Page 8: ...ption of the component Non contact safety sensor with integrated AS i Safety at Work Relevant Directives 2006 42 EC 2014 53 EU 2011 65 EU Machinery Directive RED Directive RoHS Directive Applied stand...

Reviews: