background image

EN

Operating instructions           pages 1 to 10

Original

RSS 36 

Operating instructions

Safety sensor

EN

1

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure the safe 

operation and disassembly of the safety switchgear The operating 

instructions must be available in a legible condition and a complete 

version in the vicinity of the device

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation

The machine builder must carefully select the harmonised standards 

to be complied with as well as other technical specifications for the 

selection, mounting and integration of the components

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional  

information

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine

1.4  Appropriate use

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the correct functionality of the entire machine or plant

The safety switchgear must be exclusively used in accordance with 

the versions listed below or for the applications authorised by the 

manufacturer Detailed information regarding the range of applications 

can be found in the chapter "Product description"

1.5  General safety instructions

The user must observe the safety instructions in this operating 

instructions manual, labelled with the caution or warning symbol above, 

the country-specific installation standards as well as all prevailing safety 

regulations and accident prevention rules

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

wwwschmersalnet

Content

x

000 / 01

2020 / v

A

   -   103014104-EN / G / 2020-01-27 / 

AE-Nr

 1

1919

1  About this document

11  Function                                              1

12 

Target group: authorised qualified personnel

                 1

13  Explanation of the symbols used                           1

14  Appropriate use                                         1

15  General safety instructions                                1

16  Warning about misuse                                   2

17  Exclusion of liability                                      2

2  Product description

21  Ordering code                                          2

22  Special versions                                       2

23  Comprehensive quality insurance to 2006/42/EC               2

24  Purpose                                               2

25  Technical data                                          2

26 

Safety classification

                                    3

3  Mounting

31  General mounting instructions                             3

32  Dimensions                                            4

33  Switch distance                                         4

34  Adjustment                                           4

4  Electrical connection

41  General information for electrical connection                 5

42  Serial diagnostic -SD                                    5

5  Operating principles and coding

51  Mode of operation of the safety outputs                     5

52  Coding                                                5

6  Diagnostic functions

61  Operating principle of the diagnostic LEDs                    6

62  Operating principle of the electronic diagnostic output           6

63  Safety-sensors with serial diagnostic function                 7

7  Set-up and maintenance

71  Functional testing                                      8

72  Maintenance                                           8

8  Disassembly and disposal

81  Disassembly                                          8

82  Disposal                                              8

9  Appendix

91 

Wiring configuration and connector accessories

              8

92  Wiring examples                                        9

10  EU Declaration of conformity

Summary of Contents for RSS 36

Page 1: ...plant The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of app...

Page 2: ...electronic safety sensor is designed for application in safety circuits and is used for monitoring the position of movable safety guards In this application the safety sensor monitors the position of...

Page 3: ...ay not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Le pr sent appareil est conforme aux CNR d Industrie...

Page 4: ...sao 10 10 sar 20 20 With the combination of old sensor new actuator V2 there may be limitations in availability owing to the reduced sao 8 mm This change has no affect on the performance level The si...

Page 5: ...nF Accessories for the series wiring For convenient wiring and series wiring of SD components the SD junction boxes PFB SD 4M12 SD variant for the field and PDM SD 4CC SD variant for control cabinet o...

Page 6: ...er guarantee the function of the safety sensor internal errors cause the safety outputs to be disabled within the risk time Any error that does not immediately affect the safe functionality of the saf...

Page 7: ...causes the safety outputs to be disabled after 30 minutes The safety outputs initially remain enabled This enables the shutdown of the process in a controlled manner An error warning is deleted when...

Page 8: ...the safety guard for instance by means of replacement actuators Damaged or defective components must be replaced 9 Appendix 9 1 Wiring configuration and connector accessories Function safety switchgea...

Page 9: ...X2 Y2 1 2 3 5 6 8 X1 X2 A1 A2 Y1 Y2 1 2 3 5 6 8 X1 4 Y1 4 Y1 X2 7 Y2 7 Y2 OUT A1 A2 OUT SPS PLC 24 VDC GND RST 36 RSS 36 RST 36 RSS 36 Y1 and Y2 Safety outputs Safety monitoring module Wiring example...

Page 10: ...ertificate 01 205 5115 02 19 Person authorised for the compilation of the technical documentation Oliver Wacker M ddinghofe 30 42279 Wuppertal The currently valid declaration of conformity can be down...

Reviews: