EU Declaration of conformity

Name of the component:

RSS 36

Type:

See ordering code

Description of the component:

Non-contact safety sensor

Relevant Directives:

2006/42/EC

2014/53/EU

2011/65/EU

Machinery Directive

RED-Directive

RoHS-Directive

Applied standards:

EN 60947-5-3:2013, 

EN 300 330 V211:2017,

ISO 14119:2013, 

EN ISO 13849-1:2015, 

IEC 61508 parts 1-7:2010,

EN 62061:2005 + AC:2010 + A1:2013 + A2:2015

Notified body for the prototype test:

TÜV Rheinland Industrie Service GmbH

Am Grauen Stein, 51105 Köln

ID n°: 0035

EC-prototype test certificate:

01/205/511502/19

Person authorised for the compilation  

of the technical documentation:

Oliver Wacker

Möddinghofe 30

42279 Wuppertal

The currently valid declaration of conformity can be  

downloaded from the internet at wwwschmersalnet

K.A. Schmersal GmbH & Co. KG

Möddinghofe 30, 42279 Wuppertal

Germany

Phone:  +49 202 6474-0

Telefax:  +49 202 6474-100

E-Mail: [email protected]

Internet: www.schmersal.com

Place and date of issue:

Wuppertal, January 8, 2020

Authorised signature

Philip Schmersal

Managing Director

EU Declaration of conformity

Original

KA Schmersal GmbH & Co KG

Möddinghofe 30

42279 Wuppertal

Germany

Internet: wwwschmersalcom

We hereby certify that the hereafter described components both in their basic design and construction conform 

to the applicable European Directives 

Summary of Contents for RSS 36

Page 1: ...plant The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of app...

Page 2: ...electronic safety sensor is designed for application in safety circuits and is used for monitoring the position of movable safety guards In this application the safety sensor monitors the position of...

Page 3: ...ay not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Le pr sent appareil est conforme aux CNR d Industrie...

Page 4: ...sao 10 10 sar 20 20 With the combination of old sensor new actuator V2 there may be limitations in availability owing to the reduced sao 8 mm This change has no affect on the performance level The si...

Page 5: ...nF Accessories for the series wiring For convenient wiring and series wiring of SD components the SD junction boxes PFB SD 4M12 SD variant for the field and PDM SD 4CC SD variant for control cabinet o...

Page 6: ...er guarantee the function of the safety sensor internal errors cause the safety outputs to be disabled within the risk time Any error that does not immediately affect the safe functionality of the saf...

Page 7: ...causes the safety outputs to be disabled after 30 minutes The safety outputs initially remain enabled This enables the shutdown of the process in a controlled manner An error warning is deleted when...

Page 8: ...the safety guard for instance by means of replacement actuators Damaged or defective components must be replaced 9 Appendix 9 1 Wiring configuration and connector accessories Function safety switchgea...

Page 9: ...X2 Y2 1 2 3 5 6 8 X1 X2 A1 A2 Y1 Y2 1 2 3 5 6 8 X1 4 Y1 4 Y1 X2 7 Y2 7 Y2 OUT A1 A2 OUT SPS PLC 24 VDC GND RST 36 RSS 36 RST 36 RSS 36 Y1 and Y2 Safety outputs Safety monitoring module Wiring example...

Page 10: ...ertificate 01 205 5115 02 19 Person authorised for the compilation of the technical documentation Oliver Wacker M ddinghofe 30 42279 Wuppertal The currently valid declaration of conformity can be down...

Reviews: