8.3  Actuator configuration

Enabling circuits (Fig. 18 and 19)

All safety-monitoring modules with control category 4 or PLe from the 

Schmersal Group with current < 1 A in the monitoring circuit can be 

connected to the Protect-PE-02 and Protect-PE-11 devices.

13

23

14

24

S11

S21

S12

S22

13

23

14

24

a)

PROTECT-

PE-02 /

PE-11

K1

K3

K5

K2

K4

K6

K7

K8

K1

K2

Fig. 18: PROTECT-PE-02 / PROTECT-PE-11

a) Safety-monitoring module, e.g. SRB301MC, SRB301ST, SRB211ST, …

•  All safety-monitoring modules from the Schmersal Group, which are 

suitable for setting up an antivalent input circuit, can be connected to 

the PROTECT-PE-11-AN.

13

21

14

22

S13

S21

S14

S22

13

23

14

24

a)

PROTECT-

PE-11-AN

K1

K3

K5

K2

K4

K6

K7

K8

K1

K2

Fig. 19: PROTECT-PE-11-AN
a) Safety-monitoring module, e.g. SRB301AN, SRB211AN, AES1337, …

The safety-monitoring modules must be suitable for the signal 

processing of 1- or 2-channel potential-free NC contacts or, 

for the version PROTECT-PE-11-AN, for a combination of 

NC/NO contacts. The start and actuator configuration must 

be realised in accordance with this operating instructions 

manual.

Signalling outputs (see fig. 20 and 21)

•  The LED's or the signal outputs indicate that the safety guard or the 

emergency stop circuit is opened.

•  Both contact circuits of a sensor are monitored.

•  If the safety guard or the emergency stop circuit is opened, a 

24V signal is activated at the output concerned (Y1...Y4) and Y5 

(summation signal) and the allocated LED's are lit.

•  If one or more safety guards or emergency stop circuits are opened, 

the signalling contact 33-34 is closed and the signalling contact 32-33 

is opened.

K2

Y1

A1

A2

K1

K4

Y2

K3

K6

Y3

K5

K8

Y4

K7

K1

K2

K3

K4

K5

K6

K7

K8

Y1

Y2

Y3

Y4

Y5

Fig. 20

K1 … K8

33

32

34

Fig. 21

Auxiliary contacts must not be used in safety circuits.

Cascading (Fig. 22 and 23)

•  In this way, up to 20 components can be wired in series. 

 

This corresponds to a signal processing of up to 80 sensors.

13

14

23

24

PROTECT-PE-02

PROTECT-PE-11

PROTECT-PE-02

PROTECT-PE-11

PROTECT-PE-02

PROTECT-PE-11

PROTECT-PE-02

PROTECT-PE-11

13

14

23

24

13

14

23

24

13

14

23

24

S11

S12

S21 S22

a)

      

      

Fig. 22: a) Safety-monitoring module, e.g. SRB301MC, SRB301ST, 

SRB211ST, …

13

14

21

22

PROTECT-

PE-11-AN

PROTECT-

PE-11-AN

PROTECT-

PE-11-AN

PROTECT-

PE-11-AN

13

14

21

22

13

14

21

22

13

14

21

22

S21 S22 S13

S14

a)

      

      

Fig. 23: a) Safety-monitoring module, e.g. SRB301AN, SRB211AN, …

Summary of Contents for PROTECT-PE

Page 1: ...r must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in...

Page 2: ...the compliance with the Machinery Directive is maintained 2 2 Special versions For special versions which are not listed in the order code below 2 1 these specifications apply accordingly provided th...

Page 3: ...he below mentioned switching cycle times tcycle for the relay contacts Contact load nop y tcycle 20 525 600 1 0 min 40 210 240 2 5 min 60 75 087 7 0 min 80 30 918 17 0 min 100 12 223 43 0 min Divergin...

Page 4: ...ted and observed S5 S1 S6 S3 S4 S7 S8 S2 SW1 SW2 SW3 SW4 nQS QS nQS QS nQS QS nQS QS S5 S1 S6 S3 S4 S7 S8 S2 SW1 SW2 SW3 SW4 nQS QS nQS QS nQS QS nQS QS Fig 4 Fig 5 6 Set up and maintenance 6 1 Functi...

Page 5: ...gnalling outputs Dual channel control of a safety related electronic micro processor based safety guard with p type transistor outputs e g AOPD s to EN 61496 1 see Fig 14 only PROTECT PE 02 The contro...

Page 6: ...ith this operating instructions manual Signalling outputs see fig 20 and 21 The LED s or the signal outputs indicate that the safety guard or the emergency stop circuit is opened Both contact circuits...

Page 7: ...approved the full quality assurance system referred to in Appendix X 2006 42 EC T V Rheinland Industrie Service GmbH Alboinstr 56 12103 Berlin ID n 0035 Person authorized for the compilation of the te...

Page 8: ...A Schmersal GmbH Co KG M ddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal c...

Reviews: