background image

PROTECT-PE

Operating instructions

Input expander module

EN

1

1. About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure the safe 

operation and disassembly of the safety switchgear. The operating 

instructions must be available in a legible condition and a complete 

version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards 

to be complied with as well as other technical specifications for the 

selection, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine. It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the correct functionality of the entire machine or plant.

The safety switchgear must be exclusively used in accordance with 

the versions listed below or for the applications authorised by the 

manufacturer. Detailed information regarding the range of applications 

can be found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating 

instructions manual, the country-specific installation standards as well 

as all prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

www.schmersal.net.

The information contained in this operating instructions manual is 

provided without liability and is subject to technical modifications.

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed.

Content

1  About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2 

Target group: authorised qualified personnel

. . . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.4  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.5 

Safety classification

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3  Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

4  Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . .3

5  Operating principle and settings

5.1  LED functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

5.2  Description of the terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

5.3  Notes  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

6  Set-up and maintenance

6.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

6.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

7  Disassembly and disposal

7.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

7.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

8  Appendix

8.1  Wiring example  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

8.2 

Sensor configuration

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

8.3 

Actuator configuration

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

9  EU Declaration of conformity

x.000 / 07.2016 / v

.A.   -   10121

1895-EN / D / 2016-07-13 / 

AE-Nr

. 6296

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 8

Original

Summary of Contents for PROTECT-PE

Page 1: ...r must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in...

Page 2: ...the compliance with the Machinery Directive is maintained 2 2 Special versions For special versions which are not listed in the order code below 2 1 these specifications apply accordingly provided th...

Page 3: ...he below mentioned switching cycle times tcycle for the relay contacts Contact load nop y tcycle 20 525 600 1 0 min 40 210 240 2 5 min 60 75 087 7 0 min 80 30 918 17 0 min 100 12 223 43 0 min Divergin...

Page 4: ...ted and observed S5 S1 S6 S3 S4 S7 S8 S2 SW1 SW2 SW3 SW4 nQS QS nQS QS nQS QS nQS QS S5 S1 S6 S3 S4 S7 S8 S2 SW1 SW2 SW3 SW4 nQS QS nQS QS nQS QS nQS QS Fig 4 Fig 5 6 Set up and maintenance 6 1 Functi...

Page 5: ...gnalling outputs Dual channel control of a safety related electronic micro processor based safety guard with p type transistor outputs e g AOPD s to EN 61496 1 see Fig 14 only PROTECT PE 02 The contro...

Page 6: ...ith this operating instructions manual Signalling outputs see fig 20 and 21 The LED s or the signal outputs indicate that the safety guard or the emergency stop circuit is opened Both contact circuits...

Page 7: ...approved the full quality assurance system referred to in Appendix X 2006 42 EC T V Rheinland Industrie Service GmbH Alboinstr 56 12103 Berlin ID n 0035 Person authorized for the compilation of the te...

Page 8: ...A Schmersal GmbH Co KG M ddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal c...

Reviews: