Operating instructions

Input expander module

PROTECT-PE

EN

1.6  Warning about misuse

In case of improper use or manipulation of the safety switch-

gear, personal hazards or damages to machinery or plant 

components cannot be excluded when safety switchgear is 

used. The relevant requirements of the standards ISO 14119 

and ISO 13850 must be observed.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual. The manufacturer shall accept no liability for damages 

resulting from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary 

repairs, conversions and modifications to the device are strictly 

forbidden; the manufacturer shall accept no liability for damages 

resulting from such invasive work, arbitrary repairs, conversions and/or 

modifications to the device.

The input expander module PROTECT-PE-02 / …-PE-02-SK must only 

be used when the enclosure is closed, i.e. with the front cover fitted.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

PROTECT-PE-

-

No. Option

Description

➀ 

02

Connection of NC/NC sensors

11

Connection of NC/NO sensors

11-AN

Connection of NC/NO sensors 

outputs with antivalent enabling contacts

with cage clamps

SK

with plug-in screw connection

• 

 Possibility to connect up to 4 sensors per interface, e.g. 

safety magnetic switches of the BNS type, emergency stop 

control devices, interlocking devices, etc.

•  

Wiring of up to 4 sensors per interface with signals connected 

to the potential possible, e.g. CSS type electronic safety 

sensors and AOPD’s (only PROTECT-PE-02)

• 

 Current and voltage limitation of the input circuits

• 

 Cross-wire monitoring of the input circuits

• 

 Signalling output for each sensor (monitoring of both circuits 

of the sensors)

•  

Signalling output summation signal of all sensors and one 

summation signal signalling contact (NC + NO)

• 

Green LED indications for U

i

 and every sensor contact

• 

 Cascading possible for the connection of up to 80 sensors

This device is designed as input expander module. The 

safety function is only realised in conjunction with the 

downstream basic device (SRB). To this effect, the device 

must be connected in accordance with the wiring example!

Only if the information described in this operating instructions 

manual are realised correctly, the safety function and therefore 

the compliance with the Machinery Directive is maintained.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 

these specifications apply accordingly, provided that they correspond to 

the standard version.

2.3  Destination and use

The input expander modules for integration in safety circuits are 

designed for fitting in control cabinets. They are used for the evaluation 

of the signals of 1...4 sensors and the summarised transmission of the 

signals to a downstream safety-monitoring module.

The function is defined as the opening of the enabling contacts 13-14 

and 23-24 (in variant AN the opening of 13-14 and the closing of 21-22) 

when one or more of the 8 sensor inputs are actuated. The enabling 

paths with the outputs contacts 13-14 and 23-24 (21-22) meet the 

following requirements under observation of a PFH value assessment 

and in conjunction with an SRB (control category 4 / PLe)  

(also refer to chapter 2.5 "Safety classification"):

–  Control category 3 – PL d to ISO 13849-1 (when multiple  

safety guards are opened within one work cycle)

– SIL 2 to IEC 61508

–  SILCL 2 to EN 62061

refer to folder:

http://www.schmersal.net/Bilddata/broschue/k-info/i_diap01.pdf  

(german)

http://www.schmersal.net/Bilddata/broschue/k-info/i_diap02.pdf  

(english)

The above-described requirements cannot be met by the 

input expander module solely, but only in combination with a 

safety-monitoring module as described in this manual.

To determine the Performance Level (PL) to ISO 13849-1 of the entire 

safety function (e.g. sensor, logic, actuator), an assessment of all 

relevant components is required.

The entire concept of the control system, in which the safety 

component is integrated, must be validated to the relevant 

standards.

2.4  Technical data

General data:

Standards:

 

EN 60204-1, IEC 60947-5-1;  

ISO 13849-1, IEC 61508

Climate resistance:

 

EN 60068-2-78

Mounting:

 

snaps onto standard  

DIN rail to EN 60715

Terminal designations:

 

IEC 60947-1

Material of the housings:

 

Plastic, thermoplastic

Material of the contacts:

 AgSnO

Weight:

 

160 g

Start conditions:

 Automatic

Feedback circuit (Y/N):

 No

Pull-in delay:

 

≤ 10 ms

Drop-out delay in case of "emergency stop":

 

≤ 10 ms 

Drop-out delay on "supply failure":

 

≤ 60 ms

Mechanical data:

Connection type:

 

Cage clamps;  

- SK variant:

 

plug-in screw connection

Cable section: 

 

- Cage clamps:

 

min. 0.08 mm² / max. 2.5 mm²

  

- Screw connection:

 

min. 0.14 mm² / max. 1.5 mm²

Connecting cable:

 

rigid or flexible

Tightening torque for the terminals: 

 

0.6 Nm

With removable terminals (Y/N):

 

SK variant: Yes

Mechanical life:

 

10 million operations

Electrical life: 

 

Derating curve available  

on request

Resistance to shock:

 

30 g / 11 ms

Resistance to vibrations to EN 60068-2-6:

 

10 ... 55 Hz,  

amplitude 0.35 mm

Summary of Contents for PROTECT-PE

Page 1: ...r must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in...

Page 2: ...the compliance with the Machinery Directive is maintained 2 2 Special versions For special versions which are not listed in the order code below 2 1 these specifications apply accordingly provided th...

Page 3: ...he below mentioned switching cycle times tcycle for the relay contacts Contact load nop y tcycle 20 525 600 1 0 min 40 210 240 2 5 min 60 75 087 7 0 min 80 30 918 17 0 min 100 12 223 43 0 min Divergin...

Page 4: ...ted and observed S5 S1 S6 S3 S4 S7 S8 S2 SW1 SW2 SW3 SW4 nQS QS nQS QS nQS QS nQS QS S5 S1 S6 S3 S4 S7 S8 S2 SW1 SW2 SW3 SW4 nQS QS nQS QS nQS QS nQS QS Fig 4 Fig 5 6 Set up and maintenance 6 1 Functi...

Page 5: ...gnalling outputs Dual channel control of a safety related electronic micro processor based safety guard with p type transistor outputs e g AOPD s to EN 61496 1 see Fig 14 only PROTECT PE 02 The contro...

Page 6: ...ith this operating instructions manual Signalling outputs see fig 20 and 21 The LED s or the signal outputs indicate that the safety guard or the emergency stop circuit is opened Both contact circuits...

Page 7: ...approved the full quality assurance system referred to in Appendix X 2006 42 EC T V Rheinland Industrie Service GmbH Alboinstr 56 12103 Berlin ID n 0035 Person authorized for the compilation of the te...

Page 8: ...A Schmersal GmbH Co KG M ddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal c...

Reviews: