schmersal EX-BNS 250-2187 Operating Instructions Manual Download Page 6

K. A. Schmersal GmbH & Co. KG

Industrielle Sicherheitsschaltsysteme

Möddinghofe 30, D - 42279 Wuppertal

Postfach 24 02 63, D - 42232 Wuppertal 

Phone:  +49 - (0)2 02 - 64 74 - 0 

Telefax  +49 - (0)2 02 - 64 74 - 1 00

E-Mail:  [email protected]

Internet:  http://www.schmersal.com

Summary of Contents for EX-BNS 250-2187

Page 1: ...anufac turer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country specific installation standards as well as all prevailing safety regulations and accident prevention rules Further technical information can be found in ...

Page 2: ...safety monitoring module is technically possible To connect multiple safety sensors check if au thorised the NC contacts of channel 1 are wired in series and the NC contacts of channel 2 are wired in series The channels 1 and 2 must be wired separatedly to the safety monitoring module Recommended suitable safety monitoring modules The following safety monitoring modules of the AES AZR and SRB seri...

Page 3: ...spacer must be used The use of non magnetic fixing screws is rec ommended as well Do not subject the safety sensor and actuator to extreme vibrations and shocks Keep away from metal chips The mounting distance between two sensors should always be at least 50 mm Please observe the specifications for the maximum impact energy in the technical data 3 2 Dimensions All measurements in mm Safety sensor ...

Page 4: ...maintenance 5 1 Functional testing The safety function of the safety components must be tested The fol lowing conditions must be previously checked and met 1 The installation is executed according to the instructions 2 The connection is executed correctly 3 The safety component is not damaged 4 The system is free of dirt and soiling in particular metal chips 5 Check cable entry and connections in ...

Page 5: ...vant EC Directives 2006 42 EC EC Machinery Directive 94 9 EC EC Explosion Protection Directive ATEX Person authorized for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue Wuppertal September 24 2012 Authorised signature Philip Schmersal Managing Director EC Declaration of conformity Translation of the original Declaration of Confor...

Page 6: ...o KG Industrielle Sicherheitsschaltsysteme Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...